Encoder Power Supply - Siemens Simodrive 611 Configuration Manual

Drive converters
Hide thumbs Also See for Simodrive 611:
Table of Contents

Advertisement

05.08
05.01
Incremental systems with two sinusoidal voltage signals A, B offset by
90 degrees (several, for distance–coded systems) reference mark(s) R.
Transfer:
Amplitude A – *A
Amplitude B – *B
Amplitude R – *R
Power supply:
Max. power supply current:
Max. processable enc. signal frequency:
Note
For the above specified max. encoder signal frequency, the signal amplitude
must be
from the ideal 90
Observe the frequency characteristic of the encoder signals.
Fig. 3-3
1) Refer to parameterizable encoder limit frequency (as of SW 5.1.14)
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
3 Motor Selection, Position/Speed Sensing

60% of the nominal amplitude and the deviation of the phase shift
d
between track A and B must be
A–*A
0
90_ el.
360_ el.
B–*B
0
Range of uniqueness
R–*R
0
Signal characteristic for a clockwise direction of rotation
3.4 Direct position sensing
Differential signals
A, *A; B, *B and R, R*
1 Vpp + +20% –25%
1 Vpp + 20% –25%
0.2 Vpp ... 1 Vpp
5 V ± 5% (also refer to Chapter 3.4.2

Encoder power supply)

300 mA
200 kHz standard module/
1)
420 kHz (as of SW 5.1.14)
350 kHz
d
 
30
.
3
3-69