Signal Amplifier Electronics - Siemens Simodrive 611 Configuration Manual

Drive converters
Hide thumbs Also See for Simodrive 611:
Table of Contents

Advertisement

3 Motor Selection, Position/Speed Sensing
3.4 Direct position sensing
3.4.4

Signal amplifier electronics

3-76
The signal amplifier electronics (SVE) is used for encoders with current signals
between the encoder and drive module to convert the current signals into volta-
ge signals 1 Vpp .
The signal amplifier electronics were developed for optical encoder systems
equipped with photodiodes and no additional supplementary electronics (exam-
ple, ROD 456 from the Heidenhain company). However, there are many encod-
er systems in the market with integrated electronics where the behavior of cur-
rent signals is only roughly emulated. As a result of the many options available,
a general statement regarding the compatibility between the encoder, SVE and
closed–loop control cannot be made.
Notice
For new applications, no longer use encoders with current signals, as voltage
signals offer a higher noise immunity.
The signal amplification electronics can be used in conjunction with the
following control modules:
S
SIMODRIVE 611 digital High Standard or High Performance
S
SIMODRIVE 611 universal HRS/E HRS for encoders with sin/cos 1Vpp
S
HLA module
S
ANA module
Table 3-2
Technical data of the signal amplifier electronics
Technical specifications
Signal shape
Input signal
Output signal
Max. signal frequency
Max. operating voltage
At the remote sense
Max. operating current
Encoder voltage supply
Max. encoder current supply
Dimensions (W x H x D)
Order number
Housing degree of protection
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
Sine/cosine
7 μA
to 16 μA
PP
PP
1V
PP
300 kHz
8 VDC
200 mA
5 VDC $5%
120 mA
54 mm x 121 mm x 57 mm
6SN1115–0AA12–0AA0
IP65