Siemens Simodrive 611 Configuration Manual page 149

Drive converters
Hide thumbs Also See for Simodrive 611:
Table of Contents

Advertisement

6 Infeed Modules
6.2 Interface overview
Table 6-1
Interface description for NE modules, continued
Term.
Designa-
Function
No.
tion
P600
DC link
M600
DC link
1R,
TR1,
Connection, external
9)
2R,
TR2
resistor
3R
X131
Electronics M
X151
Equipment bus
M500
X181
DC link power supply
DC link power supply
P500
X181
Output L1
Input L1
1U1
X181
Output L2
2U1
X181
Input L2
1V1
X181
Output L3
2V1
X181
Input L3
1W1
X181
2W1
X181
7
X141
P24
45
X141
P15
44
X141
N15
10
X141
N24
2)
15
X141
M
6)
R
X141
RESET
5.3
X121
Relay contact
5.2
X121
Group signal
2
5.1
X121
I
t/motor temp.
2)
63
X121
Pulse enable
2)8)
9
X121
Enable voltage
2)8)
9
X121
Enable voltage
2)
64
X121
Drive enable
19
Enable voltage
reference potential
1) I = input; O = output; NC = NC contact; NO = NO contact; (for signal, NO = high; NC = low)
P = only for PELV voltage; S = only for SELV voltage
2) Term. 19 is the reference ground (connected through 10 kW to the general reference ground X131/T.15 inside the module)
Terminal 15 must not be connected to PE, to terminal 19 or to external voltage sources.
Terminal 19 can be connected with X131.
The terminal may be used only for enabling the associated drive group.
3) I/R = infeed/regenerative feedback module; UI = unregulated infeed; MM = monitoring module;
PR = pulsed resistor module
4) The first data applies with pin–type cable lug. The second data is used for finely–stranded cable without end sleeve.
5) The grounding clip is used to ground the DC link M600 busbar through 100 kΩ (must be closed and must not be closed
if RCCBs are used, see also Chapter 8.1;
the grounding clip must be opened if the system is subject to a high–voltage test).
6) RESET = resets the fault memory, edge–triggered for the complete drive group (terminal "R" ! Terminal 15 = RESET)
7) Terminals 111–213, positively–driven opening contacts (for I/R 16 kW and UI 10 kW, only from Order No. [MLFB]:
6SN114V–1VV01–0VVV)
Terminals 111–113 NO contact not positively–driven
For I/R 16 kW (from version E) and UI 10 kW (from version F) the following apply:
Terminals 111–213, positively–driven opening contacts (series circuit of NC contact, main contactor and NC contact,
pre–charging contactor)
Terminals 111–113, positively–driven NO contacts
8) Max. current load of terminal 9 with respect to terminal 19: 0.5 A.
9) Only for UI 28 kW
10) For UL certification, only use copper cables dimensioned for an operating temperature w 60°C
11) Max. permissible connected power: Pmax v 43 kW; max. permissible current load: Imax v 72 A
12) When the AS1/AS2 contacts are connected in series a contact resistance of approx. 0.20 Ohm must be taken into
consideration over the lifetime of the contacts. For a 24 V switching voltage, from experience, a series
circuit of up to five contacts can be used without any problems due to the non–linear contact characteristics.
13) In accordance with EN 60204–1 (machine safety), control transformers must be used for AC control voltages.
6-148
Type
Typ. voltage/limit values
1)
for V
400 V
n
I/O
+300 V
I/O
–300 V
I/O
300 V
I/O
0 V
I/O
Various
I
DC –300 V
I
DC +300 V
O
3–ph. 400 V AC
I
3–ph. 400 V AC
O
3–ph. 400 V AC
I
3–ph. 400 V AC
O
3–ph. 400 V AC
I
3–ph. 400 V AC
O
+20.4...28.8 V/50 mA
O
+15 V/10 mA
O
–15 V/10 mA
O
–20.4...28.8 V/50 mA
O
0 V
I
T.15/R
= 10 kΩ
I
NC
DC 50 V/0.5 A/12 VA max
NO
DC 5 V/3 mA min
I
I
+13 V...30 V/R
= 1.5 kΩ
E
O
+24 V
O
+24 V
I
+13 V...30 V/R
= 1.5 kΩ
E
0 V
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
Max. cross–
Terminals pro-
10)
section
2
2 4)
16 mm
/10 mm
Monitoring mod-
2
2 4)
16 mm
/10 mm
ule
2
2 4)
6 mm
/4 mm
UI 28 kW
2
2
16 mm
/10 mm
4) I/R, UI, monitor-
ing module
Ribbon cable
I/R, UI, monitor-
ing module
2
1.5 mm
2
1.5 mm
2
1.5 mm
I/R, UI, monitor-
2
1.5 mm
ing module
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
I/R, UI, monitor-
2
1.5 mm
ing module
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
I/R, UI, monitor-
2
1.5 mm
2
ing module
1.5 mm
2
1.5 mm
2
1.5 mm
© Siemens AG 2012 All Rights Reserved
02.07
05.01
3)
vided on
11)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents