The actually achievable system quality with regard to speed or positioning
accuracy depends primarily on the quality of the used encoders and other
influencing factors, such as:
S
S
In practice, the previously mentioned effects mean the quality that can be
achieved in a real system is significantly lower than the theoretically achievable
quality.
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
3 Motor Selection, Position/Speed Sensing
Encoder with TTL signal
For the speed control of induction motors with SIMODRIVE 611 universal
HRS control units, sin/cos 1 Vpp variant, TTL encoders can be connected
and evaluated.
The limit frequency f
can be as high as 420 kHz.
G
The SIMODRIVE 611 universal E HRS control unit allows only one TTL sig-
nal to be passed to a higher level controller using the PROFIBUS DP.
the mechanical system (rigidity, backlash, mass (GD
the control–engineering configuration of motors, power, controller
(interpolation and control cycles, control parameters, etc.)
3.2 Motor encoder
2
)), and also
3-67