Siemens Simodrive 611 Configuration Manual page 90

Drive converters
Hide thumbs Also See for Simodrive 611:
Table of Contents

Advertisement

02.12
05.01
Encoder
connection
X421/X422
Table 4-5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Note:
The inputs on the control must not be assigned any signals other than the intended sig-
nals. Otherwise, sporadic or permanent malfunction or damage can occur.
It is especially important for spindle applications, that possibly available signals from
additional temperature sensors (PTCs, NTCs or similar) must NOT be connected to the
CP–, CN–, DP–, DN inputs that are not used when using induction motors!
When "parking axis" is selected, the encoder can be withdrawn and inserted also under
voltage.
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
4.1 Closed–loop control with digital setpoint interface
Encoder signal input of direct measuring system X421. X422
Pin
X421 (axis 1)
X422 (axis 2)
PENC
Encoder power supply
MENC
Encoder power supply ground
AP
Incremental signal for track A
AN
Inverse incremental signal for track A
ENDATDAT
Data signal EnDat interface
BP
Incremental signal for track B
BN
Inverse incremental signal for track B
XENDATDAT
Inverse EnDat interface data signal
PSENSE
Remote sense encoder power supply (P)
RP
Reference mark signal/zero pulse
MSENSE
Remote sense encoder power supply (N)
RN
Inverse reference mark signal/zero pulse
M
Inner shield ground
ENDATCLK
EnDat interface clock signal
XENDATCLK
Inverse clock signal, EnDat interface
4 Control Units
Function
4-89
4