Download  Print this page

GE C30 Instruction Manual Page 290

Controller system.
Hide thumbs
   
1
2
Table of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416

Advertisement

FLEXLOGIC
Some operands can be re-named. These are the names of the breakers in the breaker control feature, the ID (identification)
of contact inputs and outputs, the ID of virtual inputs, and the ID of virtual outputs. If the user changes the default name or
ID of any of these operands, the assigned name appears in the relay list of operands. The default names are shown in the
FlexLogic operands table.
The characteristics of the logic gates are tabulated in the following table, and the operators available in FlexLogic are
listed in the FlexLogic operators table.
Table 5-19: FlexLogic gate characteristics
Gates
NOT
OR
AND
NOR
NAND
XOR
Table 5-20: FlexLogic operators
Type
Syntax
Editor
INSERT
DELETE
End
END
One-shot
POSITIVE ONE SHOT
5
NEGATIVE ONE SHOT
DUAL ONE SHOT
Logic
NOT
gate
OR(2)
OR(16)
AND(2)
AND(16)
NOR(2)
NOR(16)
NAND(2)
NAND(16)
XOR(2)
LATCH (S,R)
Timer
TIMER 1
TIMER 32
Assign
= Virt Op 1
virtual
output
= Virt Op 96
5-134
Number of inputs
Output is '1' (= ON) if...
1
input is '0'
2 to 16
any input is '1'
2 to 16
all inputs are '1'
2 to 16
all inputs are '0'
2 to 16
any input is '0'
2
only one input is '1'
Description
Insert a parameter in an equation list
Delete a parameter from an equation list
The first END encountered signifies the last entry in
the list of processed FlexLogic parameters
One shot that responds to a positive going edge
One shot that responds to a negative going edge
One shot that responds to both the positive and
negative going edges
Logical NOT
2 input OR gate
16 input OR gate
2 input AND gate
16 input AND gate
2 input NOR gate
16 input NOR gate
2 input NAND gate
16 input NAND gate
2 input Exclusive OR gate
Latch (set, reset): reset-dominant
Timer set with FlexLogic timer 1 settings
Timer set with FlexLogic timer 32 settings
Assigns previous FlexLogic operand to virtual
output 1
Assigns previous FlexLogic operand to virtual
output 96
CHAPTER 5: SETTINGS
Notes
A 'one shot' refers to a single input gate that
generates a pulse in response to an edge on
the input. The output from a 'one shot' is
True (positive) for only one pass through the
FlexLogic equation. There is a maximum of
64 'one shots.'
Operates on the previous parameter
Operates on the 2 previous parameters
Operates on the 16 previous parameters
Operates on the 2 previous parameters
Operates on the 16 previous parameters
Operates on the 2 previous parameters
Operates on the 16 previous parameters
Operates on the 2 previous parameters
Operates on the 16 previous parameters
Operates on the 2 previous parameters
The parameter preceding LATCH(S,R) is the
reset input. The parameter preceding the
reset input is the set input.
The timer is started by the preceding
parameter. The output of the timer is
TIMER #.
The virtual output is set by the preceding
parameter
C30 CONTROLLER SYSTEM – INSTRUCTION MANUAL

Advertisement

Table of Contents

   Also See for GE C30

   Related Manuals for GE C30

Comments to this Manuals

Symbols: 0
Latest comments: