Input Specifications
THERMOCOUPLE
TYPE
RANGE
J
0 TO 760C
0 TO 1400F
K
0 TO 1370C
0 TO 2500F
T
-200 TO 400C
-330 TO 750F
R
200 TO 1650C
400 TO 3000F
S
200 TO 1650C
400 TO 3000F
RTD
100 ohm
(.00385 OHM/OHM/C)
-140 to 400C
-220 to 750F
MILLIAMPS
* 0 to 20 mADC
* 4 to 20 mADC is accommodated via the 1-5 VDC input
selection with the addition of a shunt resistor.
SENSOR FAULT DETECTION
Displays Hi or Lo process input for thermocouple or RTD inputs (10% above or below
range) and sensor break, SnSr. On/Off outputs go off, proportional outputs go to user
selectable output %. Sensor fault detection is not functional for 0 to 5 VDC.
TYPE
RANGE
E
0 TO 750C
0 TO 1400F
B
200 TO 1800C
400 TO 3300F
N
0 TO 1300C
0 TO 2370F
C
200 TO 2300C
390 TO 4170F
VOLTS
0 to 5 VDC
1 to 5 VDC
MILLIVOLTS
0 to 25 mVDC
0 to 50 mVDC
10 to 50 mVDC
REMOTE
SETPOINT
0 to 5 VDC
1 to 5 VDC