Keithley 199 Instruction Manual page 7

System dmm scanner
Hide thumbs Also See for 199:
Table of Contents

Advertisement

199 Front Panel Operation
TRIG SETUP
SHIFT/TRIG SETUP
to enter nwnu.
NEXT to scroll to next menu option.
r
Trigger
A:'
DELAY
r
INTERVAL
A/W
L
CONTINUOUS:
Reading,
scanning,
and storing
rates contmlled
by INTERVAL.
ONE SHcrT.
Osec to 999.999sec
SELECT OFF: Interval
2I75msec.
depending
on
other programmed
parameters.
SELECT ON: User-pmgrammed
interval (Ismsec to
999.9994.
DMM SETUP
SHIFUDMM
SETUP to enter menu.
NEXT to scroll to next menu option,
REV
MUX
IEEE
FREQ
SAW
LEDS
DEBUG
NSET
Displays current software revision level.
MUX OFF: Turns off autocal mufir%
for faster
reading rates.
MUX ON: Recommended
for best accuracy.
Use numeric keys to program IEEE-488 ptimary ad-
dress (O-30).
FREQ=SOHZ.
Line Frequency.
FREQ=60HZ.
Line frequency.
SAVE YES: Saves present configuration.
SAVE NO
LEDS ON: Test front panel LEDs and annunciators.
LEDS OFF
DEBUG YES: Enter troubleshooting
mode.
DEBUG NO
RESET
YES:
Returns
unit
to factory
default
configuration.
RESET NO
ONE-SH(TT OPERATION
In the oneshot
trigger mode, each reading consists of multiple conver-
sions to fill the Running Average User Filter (30 canvenions),
or the Run-
ning Average Internal Filter (5%d only, varies by ranges and function--
see manual).
For this reason,
trigger-to-reading
time could be several
seconds, depending on iiltering. When filters are off ('TO" command wer
the bus can be SAvEd), readings are made up of only one conversion.
STORE
- SHIFT/STORE to enter data store.
* SIZE = 1 to 500, or SIZE = 000 for wrap around.
* NEXT to exit size select.
- TRIGGER
to initiate storage.
* Any function key to cancel storage.
- RCL flashes when data store is full.
RECALL
* SHIFURECALL
to enter recall.
* NEXT to view data at displayed location.
* A or V to scroll through locations.
* RECALL again to select desired
location.
,,,
~,, ,,,, ,,
- NEXT to display data.
- NEXT to exit recall mode.
ERROR MESSAGES
UNCAL
OVERFL
TRIGGER
OVERRUN
INTERVAL OVERRUN
AC OI'KY
NO RANGE
CAL LOCKED
CONFIiCT
NO DATA
NO SCANNER
EEPROM failure on power up
OWTa"ge
Unit triggered while processing
reading.
Interval too short for selected configuration.
dB selected with unit not in ACV or ACA.
Pressing range button in dB.
Calibration
locked out when calibmtine
Unit in invalid state when calibrating
&.,
autorange).
Entering recall with no data stored
Scanner not installed.
TYPICAL 5% DIGIT CONVERSION
TIMES
MUX ON, DCV, ACV, AU:
1lOmsec (U3msec)
MUX OFF: Z&nsec (33msec)
MUX ON, OHMS,
3ookn range and lower: 1lOmsec (l33msec)
MUX OFF: 63msec (76msec)
(Times in parenthesis
are for 50Hz operation)
TYPICAL AUTORANGING
TIMES
DCV, DCA
35amsec
ACV, ACA
1.4sec
OHMS
(3OOkn range and
lower,
500msec
(Tffes shown are to coIIeCt range and do not include conversion times for
final reading.)