M8540Narrow, M9540Narrow, WSM
(4) Removing Air Conditioner Unit
Outer Roof and Stay
1. Remove the outer roof (1).
2. Disconnect the ground cable (2).
3. Remove the stay (3).
(When reassembling)
Outer roof mounting screw
Cabin mounting bolt and
Tightening torque
nut (M14, 9T)
Cabin mounting bolt and
nut (M12, 7T)
(1) Outer Roof
(2) Ground cable
Wiring Harness
1. Disconnect the temperature motor connector (1), and
thermostat connectors (2).
2. Disconnect the mode motor connector (3) and blower resister
connector (4).
(1) Temperature Motor Connector
(2) Thermostat Connector
N10-S18
3.5 to 4.0 N·m
0.36 to 0.40 kgf·m
2.6 to 2.9 lbf·ft
124 to 147 N·m
12.6 to 15.0 kgf·m
91.2 to 108.4 lbf·ft
77.5 to 90.2 N·m
7.9 to 9.2 kgf·m
57.2 to 66.5 lbf·ft
(3) Stay
9Y1210236CAS0033US0
(3) Mode Motor Connector
(4) Blower Resister Connector
9Y1210236CAS0034US0
KiSC issued 07, 2013 A
CABIN