SECTION 11: U30 MICROPROCESSOR SETTINGS
Symbol
LED Color
Power
Red
61
Red
6B
Green
H
Green
62
Green
BA
Green
Error
Red
Diagnostic LEDs for easy Troubleshooting
Indicates power is ON.
Activation
Holding Beam
Reduced Opening
Activation
Panic Breakout and OFF
Off
Flashing
Error Flashes
1 flash
2 flashes
3 flashes
1 flash and 2 flashes
1 flash and 3 flashes
2 flashes and 3 flashes
1 flash, 2 flashes and 3 flashes
GT1175 (H105 Medium) Hurricane Quick Set-Up and Parts Guide
Description
● Indicates a signal on the Black (61) wire.
● Black (61) wire carries the signal for the activation circuit
that will open the door from a closed position in TWO WAY
or ONE WAY mode only.
● Black (61) wire usually connects to the Interior motion
sensor.
● Indicates a signal on the White (6B) wire.
● U30 Microprocessor can be programmed to ignore
Holding Beam when door is fully closed.
● Indicates a signal on the Green (H) wire.
● The Green (H) wire carries the signal to the U30
Microprocessor Control to put the door into reduced
opening.
● Indicates a signal on the Black/Red (62) wire.
● Black/Red (62) wire carries the signal for the activation
circuit that will open the door from a closed position in
TWO WAY mode only.
● Black/Red (62) wire usually connects to the exterior
motion sensor.
● When Green LED is OFF it indicates: Closed signal on the
Blue (BA) wire or a Slide door is ready for operation
● Blue (BA) wire carries the signal for the Panic Breakout
circuit that stops Slide door operation if the Slide door is
panicked open or if the Rocker Switch is turned OFF.
● When Green LED is ON the circuit is open and the unit will
not operate.
Indicates normal operation.
Please see Error Flashing descriptions listed below.
Description
Door is in RECYCLE mode.
12VDC output is overloaded.
Indicates diagnostic error. Connect Handy Terminal to check
error details.
Recycle and 12 VDC Overload.
Recycle and diagnostic error.
12 VDC overload and diagnostic error.
Recycle; 12 VDC overload and diagnostic error.