www.NabcoEntrances.com
Rev 8-10-16
Ground Wire
On/Off
Power Switch
S1
-CIRCUIT-
-BREAKER-
RED INDICATES
POWER IS OFF
PRESS
TO
RESET
TB1
NOISE
FILTER
AC 115V ± 10%
50 / 60 Hz
4. Go to the TB1 Port located on the Left side of the Power Supply Module.
5. Insert the Incoming 120 VAC Black (HOT) wire into the Circuit marked "L".
6. Insert the Incoming 120 VAC White (Neutral) wire into the Circuit marked "N".
7. Insert Green (Grounding) wire into the Circuit marked "PE".
8. Ensure the Slide door system is Grounded for safe and consistent operation.
8 .1 Determine Correct Handing
1. With power OFF, manually slide the door half way open.
2. Turn power ON. The Slide door should slowly close (per Power On factory settings).
8 .2 Correct Wrong Handing
1. With the power ON, obtain the Cable from the Handy Terminal Case.
2. Go to the Handy Terminal Harness that is connected to the U30 Microprocessor Controller. Remove the protective Cap.
3. Connect the plug end of the Cable (that is protected with a metal sleeve), to the socket of the Handy Terminal Harness.
a. The plug end of the Cable has multiple prongs that need to line up with the socket. Gently turn the plug end clockwise
while trying to insert it until a connection can be made.
4. Connect the other end of the Cable to the Handy Terminal.
5. Press: ENTRY until the screen displays: SPECIAL FUNCTION ADJUSTMENTS Then select: Y
6. Continue pressing: ENTRY until the Screen displays: RECYCLE Change the setting.
7. Disconnect the Handy Terminal.
a. Wait at least (10) seconds before disconnecting Handy Terminal to allow last test to complete and message display
to stabilize.
8. With power OFF, manually slide the door half way open.
9. Turn power ON. The Slide door should slowly close (per Power On factory settings).
10. Plug the Handy Terminal back into the Terminal Connector.
Connect Cable to Handy Terminal
DN 0435
U30 Microprocessor Control
Power Supply
P/N V-00020
P/N V-00029
POWER SUPPLY
ASSEMBLY
P/N 9418800100
NABCO
ENTRANCES, INC.
14-11741
TB2
T1
Auxiliary 120 VAC Power wires
(These wires normally coiled and ed up)
Handy Terminal
Cable
GT1175 (H105 Medium) Hurricane Quick Set-Up and Parts Guide
12
7
0
120 VAC
U30 Microprocessor Controller
Handy Terminal Harness
Remove Protec ve Cap from Harness
P/N C-00106
Motor/Operator
P/N M-00395
WARNING
!
No.
HANDY TERMINAL・6P
MOTOR・12P
!
To protect against risk of fire
or electric shock,use only the
Microprocessor Controller
certified NABCO power supply.
248901-
Mode SW Usage
POWER
M0
M1
MODE
NABC O
Open
Open
TWO WAY
FUNCTION [SLIDING DOOR]
SYMBOL
No.
61
Gnd
Open
ONE WAY
12VDC+
9DC12V
1
GYRO TECH
12VDC-(Common)
6B
Gnd
Gnd
HOLD OPEN
7
2
Open
Gnd
NIGHT
Interior Activation
61
3
Holding Beam
H
6B
4
Reduced Opening Switch
H
5
62
!
CAUTION
M0
6
Mode Switch (see Mode SW Usage shown left)
M1
7
BA
Exterior Activation
62
8
ERROR
!
Sequential Activation
SQ
9
Adjustments to the door can only be made
Breakout Detector
BA
10
with the NABCO Handy Terminal.
Sidelite Presence Sensor
SLS
11
Contact Output (Class2 Load only)
N/O
OUT.A
12
Do not disassemble the control box.
30V(42.4Vpeak)max.
There are no user serviceable parts
N/C
OUT.B
13
5Amax.(0-20V), 3.2Amax.(20-30V)
Common
OUT.C
14
inside.
Auxiliary Output (Open-Collector)
OUT
15
!
To maintain warranty,repairs must be
12VDC-(Common)
7
16
made by authorized NABCO facilities.
DN 0647