Section 6.2: Resetting A Type 2 Control Back To A Type 1 Control; Section 6.3: Customized Programming/Settings For (1) Control Only - Nabco GT1175 Wiring And Programming Manual

Slide door opus control
Hide thumbs Also See for GT1175:
Table of Contents

Advertisement

www.NabcoEntrances.com
Rev. 8-11-21
SECTION 6.2: Resetting a Type 2 Control back to a Type 1 Control
Note:  When resseting to default the control BA is N.C. and sim pair setting is Single door.
There can never be (2) Master Controls, or (2) Slave Controls. There must always be (1) Master Control, and (1) Slave Control.
1. Go to the Control without activation devices connected to it. This will be the Slave Control (Type 1). Perform a Factory Reset.
1. Press down on the Rotary Dial until the next screen is displayed.
2. Turn the Rotary Dial clockwise to highlight (Reset to Default Set).
3. Briefly press down on the Rotary Dial. Enter the passcode: 0045.
1. Turn the Rotary Dial clockwise to highlight a preferred number, then briefly press down.
2. Repeat until the passcode is complete.
4. Briefly press down on the Rotary Dial to display the (Setting Category) Screen.
11
20
DN 2428
2. Turn the Rotary Dial to highlght (Optional Setting). Briefly press down on the Rotary Dial. Turn the Rotary Dial to highlight
(Simpair Setting). Briefly press down on the Rotary Dial to select.
3. Turn the Rotary Dial to highlight the desired Paired Setting. Briefly press down on the Rotary Dial to select.
4. Press and hold the Rotary Dial until the (Setting Category) screen is displayed.
5. Press and hold the Rotary Dial until the (Copy Data) Screen is displayed.
6. Turn the Rotary Dial to select (NO).
7. Briefly press down on the Rotary Dial. The Type 2 (Master Control) will automatically reset to the Type 1 (Slave Control).
SECTION 6.3: Customized Programming/Settings for (1) Control only
Note:  Customized Programming/Settings can be done for (1) Control without losing data previously saved for (2) Controls.
Sometimes Programming/Settings need to change for (1) Control only. For example, Door (1) needs to open faster than Door (2).
1. Go to the Type 1 (Slave Control) or Type 2 (Master Control). Program any/all new settings.
2. Press and hold the Rotary Dial until the (Copy data) Screen is displayed.
3. Turn the Rotary Dial to select (NO).
a. Customized Programming/Settings will only be saved to (1) Control.
DN 2313
Type: 2
GT1175 Opus Slide
Status:
Fully Closed
Error:
-----
Ac va on: IN EXT
Posi on:
> > > > > > > > >
Other:
BA 6B SWL
Push and Hold Dial
Go to Se ng Mode
Copy Data (SimPair)?
Yes
GT1175 Slide Door Opus Control Wiring and Programming Manual
10
Passcode
Reset to Default Set
Stroke Learning
Yes No
12
11
Type: 1
Status:
Error:
No
Ac va on: IN EXT
Posi on:
Other:
Push and Hold Dial
Go to Se ng Mode
20
Copy Data (SimPair)?
Yes
No
Reset to Default Set
0
If you don't know
the passcode,
Keep Pushing Switch,
Return to normal mode
10
GT1175 Opus Slide
Fully Closed
-----
> > > > > > > > >
BA 6B SWL
Figure 8 Reset Control
12
Figure 9 Programming/Settings for (1) Control
P/N C-00391
11 of 31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents