Table of Contents

Advertisement

Associated Manuals Part Numbers: U30 Microprocessor Control Setup and Programming Manual P/N C-00203 Model
• Turn OFF all power to the Automatic Door if a Safety System is not working.
WARNING
• Instruct the Owner to keep all power turned OFF until corrective action can be achieved
• NEVER leave a Door operating without all Safety detection systems operational.

Table of Contents

CHAPTER 1: WARNING LABELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CHAPTER 2: GENERAL SAFETY RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CHAPTER 3: SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SECTION 3.1: To the Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SECTION 3.2: Objective . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
CHAPTER 4: GETTING STARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SECTION 4.1: Types of Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SECTION 4.2: Header Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SECTION 4.3: Header Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SECTION 4.4: Remove the Header Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CHAPTER 5: INSPECT THE ROUGH OPENING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
CHAPTER 6: ASSEMBLE DOOR FRAME (NO TRANSOM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
CHAPTER 7: ASSEMBLE DOOR FRAME WITH TRANSOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SECTION 7.1: Secure Transom Verticals to Header . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SECTION 7.2: Install the Glass Stops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
SECTION 7.3: Secure Header and Transom to Pocketed Jamb Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
SECTION 7.4: Assemble Door Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
SECTION 7.5: Install the Tie Rods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
CHAPTER 8: SECURE DOOR FRAME TO BUILDING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
SECTION 8.1: Anchor Placements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
SECTION 8.2: Complete the Tie Rod Installation (For Transom Units only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Model GT1175 Standard Slide Doors Installation Manual
Nabco Entrances Inc. S82 W18717 Gemini Drive Muskego, Wisconsin 53150
Phone: (877) 622-2694 Fax: (888) 679-3319 www.nabcoentrances.com
NABCO hours of Operation: Monday to Friday 8:00 a.m.- 4:30 p.m. (Central Time)
GT1175 Electrical Installation Manual **with U30 Microprocessor Control** P/N C-00198
Automatic Sliding Door Owners Manual (P/N C-00109) for Decal Installation
NABCO Price Book P/N 16-9244-30 (for Sensors, Switches, and Accessories)
by a NABCO trained technician. Failure to follow these practices may result in serious
consequences.
**with U30 Control**
P/N C-00105 Rev 5-17-19
1 of 56

Advertisement

Table of Contents
loading

Summary of Contents for Nabco GT1175

  • Page 1: Table Of Contents

    WARNING • Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a NABCO trained technician. Failure to follow these practices may result in serious consequences. • NEVER leave a Door operating without all Safety detection systems operational.
  • Page 2 GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 CHAPTER 9: WIRE THE SWITCH ASSEMBLY (ROCKER SWITCH OR KEY SWITCH) . . . . . . . . . . 15 CHAPTER 10: INSTALL THE THRESHOLD .
  • Page 3 GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 CHAPTER 18: ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 SECTION 18.1: Balance Weight of Door Panel with Nose Caster .
  • Page 4: Chapter 1: Warning Labels

    GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 CHAPTER 1: WARNING LABELS Warning labels are universal and used to alert an individual of potential harm to one’s self or to others. The following warning labels are listed in a hierarchy order that defines the most potential danger first, and the least potential danger last. Please refer to this page in the event that a warning label is displayed within this manual and further definition needs to be explained.
  • Page 5: Chapter 3: Scope

    All installation changes and adjustments must be made by qualified, NABCO trained technicians. The GT-1175 Standard Slide Door system is designed to be installed within a Rough Opening of a Building. The door function SECTION 3 .2: Objective...
  • Page 6: Section 4.3: Header Components

    GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 Power/Operator/Control: Header Width is wide, but Operator still needs to be installed between the Power Supply and the U30 Control. U30 Microprocessor Control WARNING HANDY TERMINAL・6P To protect against risk of fire ...
  • Page 7: Chapter 5: Inspect The Rough Opening

    GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 CHAPTER 5: INSPECT THE ROUGH OPENING The width of the Rough Opening should equal: PACKAGE WIDTH 1. Ensure the Rough Opening is correct size. The height of the Rough Opening should equal: PACKAGE HEIGHT 1/4 INCH ON EACH SIDE 1/4 INCH Note: Make allowances for tile or other existing materials that may change the floor height.
  • Page 8: Chapter 7: Assemble Door Frame With Transom

    GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 3. Secure the Header to each Jamb Tube with (6) 1/4-20 x .75 Whizlock screws. a. If installed correctly there will be a 1/8 inch gap between the bottom of Jamb Tubes and the flat surface.
  • Page 9: Section 7.2: Install The Glass Stops

    Attention:  Examples shown within the Glass Stop sections are of the GT1175 Standard Slide Door . Note: Each Glass Stop is precut at the NABCO Factory according to placement and height of the Transom Vertical. Note: Glass Panels can be installed before or after the Door Frame is secured to the rough opening.
  • Page 10 GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19  7 .2 .2 Transoms and Jamb Tubes 1. Go underneath the Transom Horizontal. Snap-In Base Glass Stops between the Transom Verticals. a. Ensure the tall back of Base Glass Stops face the Exterior side of building.
  • Page 11: Section 7.3: Secure Header And Transom To Pocketed Jamb Tubes

    GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 Vinyl Vinyl Base Glass Stop Vinyl Figure 14 Install Base Glass Stops and Vinyl on Same Side DN 2146 SECTION 7 .3: Secure Header and Transom to Pocketed Jamb Tubes Note: 1175 Slide Door Units installed with a Transom are shipped with Pocket Jamb Tubes only.
  • Page 12: Section 7.5: Install The Tie Rods

    Rev 5-17-19 SECTION 7 .5: Install the Tie Rods Note:  Tie Rods are provided for Transom Units as required by NABCO Engineering. 1. Lift to position the assembled Frame into the rough opening. 2. Shim and Plumb Jamb Tubes in both planes to ensure the rough opening allows a 1/4 inch clearance.
  • Page 13: Chapter 8: Secure Door Frame To Building

    GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 Concrete Anchor Securely fasten Tie Rod to Anchor with 3/4” minimum thread engagement into building structure 3/4” Min Transom Ver cal Horizontal Transom Transom Ver cal Channel Tie Rod Leg of Backing Plate, 3/8” Flat Washer,...
  • Page 14: Section 8.1: Anchor Placements

    GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 Anchors are not provided by NABCO. SECTION 8 .1: Anchor Placements Anchors must be appropriate for the type of structure being fastened to. Screw in anchors to secure the Frame (per manufacturer’s specifications).
  • Page 15: Chapter 9: Wire The Switch Assembly (Rocker Switch Or Key Switch)

    GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 CHAPTER 9: WIRE THE SWITCH ASSEMBLY (ROCKER SWITCH OR KEY SWITCH) Jamb Tube Wire Access Hole Header Plate Wire Access Hole Female Pin Wiring Orange/White Blue Green Orange Key Switch Male Pin Housing Female Pin Housing Figure 25 Wire the Switch Assembly...
  • Page 16 GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 Threshold Screw Spline 6 x 3/8” Phillips Head Screw Screw Spline Figure 27 Secure Threshold Cap to Threshold End Cap DN 0091 3. On the same side of Door Frame where the Sidelite will be installed, snap a chalk line on the floor from Jamb to Jamb.
  • Page 17: Section 10.2: Install The Recessed Threshold

    7. With a 1/4 inch masonry drill bit, drill through the Threshold and into the floor no less than 1-1/2 inch deep. 8. Do not permanently install the Surface Threshold until the Slide Doors are completely installed. Metal Strip Fasteners not provide by NABCO Figure 34 Secure Threshold to Flat Surface DN 2114 RECESSED THRESHOLD CHAPTER 11: INSTALL THE FULL OPEN SIDELITE...
  • Page 18: Section 11.1: Install The Bottom Pivot

    GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 SECTION 11 .1: Install the Bottom Pivot 1. Go to the bottom of the Pivot Jamb Tube. Insert the Bottom Pivot into the hole. 2. Secure the Bottom Pivot to the Pivot Jamb Tube with (1) 1/4-20 x 1/2 inch Phillips Head screw.
  • Page 19: Section 11.4: Complete Installation Of The Limit Arm

    GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 Cable Wiring from Main Harness (Inside Header) Top Pivot Pivot S le Hole Spring Pin Break Out Direc on Spring Pin Figure 39 Insert Top Pivot into Header DN 2160 SECTION 11 .4: Complete Installation of the Limit Arm 1. Swing open the Swing Sidelite 90 degrees.
  • Page 20: Chapter 12: Install The Fixed Sidelite

    GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 7. Close and then break open the Swing door to test fit for both Ball Detents. a. To adjust the fit, increase the size of the hole and countersink.
  • Page 21: Section 12.2: Install The Bottom Guide Assembly

    GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 SECTION 12 .2: Install the Bottom Guide Assembly 1. Go to the bottom of Strike Stile. Remove the Bottom Guide Cover Plate. Bo om Guide Cover Plate 1/4-20 x 3/4” Phillips Screw Figure 46 Remove Bottom Guide Cover DN 0128 2. Install the Bottom Guide Double Roller Assembly by sliding (2) rollers into the Bottom Rail so the Bracket sticks out from...
  • Page 22: Chapter 13: Install The Slide Door

    GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 CHAPTER 13: INSTALL THE SLIDE DOOR SECTION 13 .1: Secure Slide Door to Belt Clips Do not test Breakout until all adjustments are made and doors are secured . CAUTION 1. Cover the Sidelite Panel with cardboard on the side that will face the Slide door.
  • Page 23: Section 13.2: Install Bottom Guides

    GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 Belt Clip Figure 53 Secure Belt Clips to Carrier 1/4”-20 x 3/4” Whiz-Lock Screw DN 1702 SECTION 13 .2: Install Bottom Guides  13 .2 .1 Insert Bottom Guide into the Threshold (Full Open Sidelite) 1. Locate the Bottom Guide Assembly that was preinstalled inside the Slide Door Strike Stile.
  • Page 24: Section 13.4: Adjust The Interlocks

    Note: Adjust Interlocks so there is no contact between the Rail and the Interlock. Any contact will cause the Slide Door to bind. 2. Obtain (1) parts bag containing (4) Shims that was taped to the Slide Door at the NABCO factory.
  • Page 25: Chapter 14: Permanently Install The Threshold

    DANGER “Electrical Installation Manual U30 Control” P/N 15-10596-30 before attempting to powerup the GT1175 Slide Door . Failure to do so may result in damage to the Slide door and/or injury to the installer and will nullify all warranties .
  • Page 26: Chapter 16: Install Weathering

    GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 Keep all incoming 120 VAC wiring separate from low voltage wiring within Header . Do not route CAUTION 120 VAC wires near the U30 Microprocessor Controller and Motor/Operator .
  • Page 27: Chapter 17: Glazing

    2. Measure (6) inches up from the Pivot End of Bottom Rail, towards the Top Rail. Mark that spot. 4. For each marked spot, place (1) Setting Block (not provided by NABCO) on top of the Base Glass Stops. 5. Place the Glass Panel on top of the Setting Blocks and up against the Vinyl.
  • Page 28: Section 17.2: Complete The Transom Installation

    Header 1. Place (1) Setting Block (not provided by NABCO) on top of the Base Glass Stops. 2. Place the Glass Panel on top of the Setting Blocks; against the Vinyl. Shift the Glass Panel until it is square.
  • Page 29: Section 17.4: Dust Protector Hoods (Clean Room Optional)

    Note: All Aluminum Hoods and Vinyl Shields are installed for Clean Room Slide Door Units only and are not manufactured by NABCO. Please call Customer Service for replacement parts at 1-888-679-3319. Note: Aluminum Hoods are installed at the bottom of each Door panel and Transom.
  • Page 30: Chapter 18: Adjustments

    GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 CHAPTER 18: ADJUSTMENTS The installation of Nose Casters depend upon the weight and size of the door panel. Please call customer service for details. SECTION 18 .1: Balance Weight of Door Panel with Nose Caster 1. Go to the Bottom Rail.
  • Page 31: Section 18.4: Adjust Horizontal Position Of Carrier

    4. Go to the back edge of Pivot Stile. Reduce Door sag by tightening the 5/16 inch Set Screw with an 5/32 inch Allen Wrench. a. In the event a longer Set Screw is necessary, an optional 1/2 inch Set Screw is supplied by NABCO within the Parts Bag.
  • Page 32: Section 18.5: Adjust The Ball Plunger

    GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 SECTION 18 .5: Adjust the Ball Plunger 1. Breakout the Slide door. Go inside the Top Rail (closest to the Strike Stile). Remove the Panic Catch Assembly. Panic Catch 1/4-20 x 1-1/4”...
  • Page 33: Service Parts: Full Open, 1175, Non-Handed

    GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 SERVICE PARTS: FULL OPEN, 1175, NON-HANDED Narrow Stile P/N A-00404; Medium Stile P/N A-00405 DN 1353 Full Open 1175 Parts Kit: P/N A-00404; A-00405 Item Part Note Description Used To M-00606 BUSHING, BOTTOM PIVOT, SWING PANEL 1 Protect inside of Barrel from dust/dirt T-00008 FHSMS,1/4x2.750L.,PHIL,TAPCON,BLUE...
  • Page 34: Service Parts: Header

    GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 34 of 56...
  • Page 35 GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 Header Item Part Finish/Sizes/Notes Description T-00061 Zinc FHMS,1/4-20x1.000L.,PHIL,TRI-LOBE,ZINC T-00022 Black Zinc FHMS,1/4-20x1.000L.,PHIL,TRI-LOBE,BLK ZN T-00010 In Part Bag A-00402 & A-00403 HHCS,1/4-20x0.750L.,WHIZLOCK,ZINC M-60582 RH/Clear END CAP,ONE PIECE HEADER,RH,204 M-70582 RH/Dark Bronze END CAP,ONE PIECE HEADER,RH,313 M-60574 LH/Clear...
  • Page 36 GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 Header Item Part Finish/Sizes/Notes Description A-00342 Fail Secure LOCK, ELECTRIC,FAIL SECURE,1175 A-00341 Fail Safe LOCK, ELECTRIC,FAIL SAFE,1175 A-00343 BRKT,BELT,ELECTRIC LOCK,RHFS,LHFO,BP A-00344 BRKT,BELT,ELECTRIC LOCK,LHFS,RHFO A-00711 “KIT,HANDY TERMINAL”...
  • Page 37: Service Parts: Fixed Sidelite

    GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 SERVICE PARTS: FIXED SIDELITE Viewed from Break Out Side DN 0598 37 of 56...
  • Page 38: Service Parts: Left Hand Fixed Sidelite

    GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 SERVICE PARTS: LEFT HAND FIXED SIDELITE Viewed from Break Out Side Holding Beam See Header DN 0600 38 of 56...
  • Page 39: Service Parts: Right Hand Fixed Sidelite

    GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 SERVICE PARTS: RIGHT HAND FIXED SIDELITE Viewed from Break Out Side Holding Beam See Header DN 0601 39 of 56...
  • Page 40 GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 Fixed Sidelite Item Part Finish/Sizes/Notes Description M-01144 SWITCH, KEY - NABCO M-01145 SWITCH, KEY - PORTA SERVICE M-00428 SWITCH MODULE,3 ROCKER,NABCO M-00429 SWITCH MODULE,3 ROCKER,PORTA M-00706...
  • Page 41: Service Parts: Fixed Sidelite Slide Door

    GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 SERVICE PARTS: FIXED SIDELITE SLIDE DOOR Viewed from Break Out Side Breakout Side DN 0584 41 of 56...
  • Page 42: Service Parts: Fixed Sidelite; Left Hand Slide Door

    GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 SERVICE PARTS: FIXED SIDELITE; LEFT HAND SLIDE DOOR Viewed from Break Out Side Use only when deemed necessary DN 0589 42 of 56...
  • Page 43: Service Parts: Fixed Sidelite; Right Hand Slide Door

    GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 SERVICE PARTS: FIXED SIDELITE; RIGHT HAND SLIDE DOOR Viewed from Break Out Side Use only when DN 0585 deemed necessary 43 of 56...
  • Page 44 GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 Fixed Sidelite Slide Door Item Part Finish/Sizes/Notes Description A-60133 Clear CARRIER END CAP,204 A-70133 Dark Bronze CARRIER END CAP,313 M-00690 WEATHER, PILE .2 T-00006 Zinc FHSMS,10x0.750L.,PHIL,ZINC...
  • Page 45 GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 Fixed Sidelite Slide Door Item Part Finish/Sizes/Notes Description T-00222 Zinc; In Part Bag A-00402 & A-00403 PHSMS,6x0.500L.,PHIL,TEKS,ZINC T-00260 Black Zinc; In Part Bag A-00402 & A-00403 PHSMS,6x0.500L. PHIL,TEKS BLK ZN M-60278 Clear HOLDER,WEATHERING BRUSH,204,EXTRU M-70278 Dark Bronze...
  • Page 46: Service Parts: Full Open Sidelite

    GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 SERVICE PARTS: FULL OPEN SIDELITE Viewed from Non-Break Out Side Non-Breakout Side DN 1035 46 of 56...
  • Page 47: Service Parts: Full Open; Left Hand Sidelite

    GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 SERVICE PARTS: FULL OPEN; LEFT HAND SIDELITE Viewed from Non-Break Out Side Holding Beam See Header DN 1037 47 of 56...
  • Page 48: Service Parts: Full Open; Right Hand Sidelite

    GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 SERVICE PARTS: FULL OPEN; RIGHT HAND SIDELITE Viewed from Non-Break Out Side Holding Beam See Header DN 1036 48 of 56...
  • Page 49 T-NUT, 3/8”-16, TIE ROD M-00462 CLIP,MUNTIN,.261 HOLE T-00061 FHMS,1/4-20x1.000L.,PHIL,TRI-LOBE,ZINC M-00428 SWITCH MODULE,3 ROCKER,NABCO M-01144 SWITCH, KEY - NABCO M-00606 In Part Bag A-00404 & A-00405 BUSHING, BOTTOM PIVOT, SWING PANEL T-00007 In Part Bag A-00404 & A-00405 FHMS,1/4-20x0.500L.,PHIL,UNDRCUT,F-PT,ZN M-00611 In Part Bag A-00404 & A-00405...
  • Page 50 GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 Full Open Sidelite Item Part Finish/Sizes/Notes Description M-60258 THRESHOLD,4-1/2 X 1/2,204,EXTRU T-00008 In Part Bag A-00404 & A-00405 FHSMS,1/4x2.750L.,PHIL,TAPCON,BLUE A-00391 KIT,SHIM,INTERLOCK 50 of 56...
  • Page 51: Service Parts: Full Open; Slide Door

    GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 SERVICE PARTS: FULL OPEN; SLIDE DOOR Viewed from Non-Break Out Side Non-Breakout Side DN 1038 51 of 56...
  • Page 52: Service Parts: Left Hand Slide Door Full Open

    GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 SERVICE PARTS: LEFT HAND SLIDE DOOR FULL OPEN Viewed from Non-Break Out Side Used only when Deemed Necessary DN 1040 52 of 56...
  • Page 53: Service Parts: Right Hand Slide Door Full Open

    GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 SERVICE PARTS: RIGHT HAND SLIDE DOOR FULL OPEN Viewed from Non-Break Out Side 36 37 Used only when DN 1039 Deemed Necessary 53 of 56...
  • Page 54 GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 Full Open Slide Door Item Part Finish/Sizes/Notes Description A-60133 Clear CARRIER END CAP,204 A-70133 Dark Bronze CARRIER END CAP,313 M-00690 WEATHER, PILE .2 T-00006 Zinc FHSMS,10x0.750L.,PHIL,ZINC...
  • Page 55 GT1175StandardSlideDoorsInstallationManual;withU30Control Rev.5-17-19 P/NC-00105 Full Open Slide Door Item Part Finish/Sizes/Notes Description M-00274 In Part Bag A-00404 & A-00405 BRUSH, NYLON, 1” STEPPED T-00105 SHSS,8-32x0.313L.,CUP PT. T-00016 Zinc FHMS,1/4-20x0.438L.,PHIL,UNDERCUT,ZINC T-00108 Black Oxide FHMS,1/4-20x0.438L.,PHIL,UNDERCUT,BLK ZN A-00198 .090 Narrow Stile NOSE CASTER ASSY, NAR A-00207 .125 Medium Stile...
  • Page 56: Service Parts: Glass Stops And Transom Hardware

    GT1175 Standard Slide Doors Installation Manual; with U30 Control www.NabcoEntrances.com P/N C-00105 Rev 5-17-19 SERVICE PARTS: GLASS STOPS AND TRANSOM HARDWARE Viewed from Break Out Side DN 0618 Glass Stops and Transom Hardware Item Part Finish/Sizes/Notes Description T-00157 “PHSMS,8x1.000L.,PHIL,TYPE B” T-00061 Zinc FHMS,1/4-20x1.000L.,PHIL,TRI-LOBE,ZINC...

Table of Contents