GT1175 (H105 Medium) Hurricane Quick Set-Up and Parts Guide
P/N C-00106
No .
Symbol Function
1
9DC 12V 12 VDC+
2
7
Common
3
61
Interior Activiation
4
6B
Holding Beam
5
H
Reduced Opening
Switch
6
M0
Mode Switch
One Way
7
M1 Night Mode Switch
8
62
Exterior Activation
9
SQ
Sequential Activation
10
BA
Breakout Detector
11
SLS
Misellaneous Input
12
OUT A
Auxiliary Output
13
OUT B
Auxiliary Output
14
OUT C
Auxiliary Output
15
OUT
Auxiliary Output 2
16
7
Common
* Color 1/Color 2 denotes a base wiring Color 1 with a Stripe Color 2 (e.g. Black/Red = Black wire with a Red Stripe)
30 of 53
16 Pin Terminal Block Assignments (All wires are identified by color)
Wire Color*
Brown
Red
Black
White
Green
Orange
* Orange/ White Input for Switch 2 (SW2):
* Black/ Red
Yellow
Blue
* Green/ White Input Terminal:
Gray
Gray
Violet
*Brown/ Yellow Terminal connected to an Internal Transistor with open collector in the
Red
Output Terminal:
● Sensor power source Output Terminal
● Output is 12 VDC with a maximum capacity of 0.35 amps (350 mA).
Output Terminal:
Provides common ground for the 12 VDC power and signal source.
Activation Signal Input:
Opens the door based on a signal from the Sensor that is active in one
way mode.
Holding Beam Input:
Opens or re-opens a door when the holding beam signal is activated.
Reduced Opening Input:
Enables reduced door opening when switched to Red (7)
Input for Switch 1 (SW1):
Used to achieve special functions.
● Used to achieve special functions.
● All references to Mode Switches are made in connection with ground
(Red).
Input Terminal:
Receives signal from a Sensor that is switched out in ONE WAY mode.
Input Terminal:
Allows a sequence of signals to open and close the door.
Input Terminal:
● Connects directly to Red (7) during normal operation.
● When the Rocker Switch is turned OFF or if the door is panicked
open, it is disconnected from Red (7) causing Slide door to stop
operating.
Receives signal from Sidelite Sensor or additional devices.
Terminal is connected to the Normally Open contact on an Internal
Relay:
● Also Referred to as the "Auxiliary Relay Output".
● Used as a switch to sequence Electric Strikes, control other doors in an
Airlock situation, or signal a Remote Computer on the door operation.
Terminal connected to the Normally Close contact on an
Relay.
Terminal is the common for output wire OUT A or OUT B.
U30 Microprocessor Control.
Terminal connected to an Internal Transistor with open collector in the
U30 Microprocessor Control.
www.NabcoEntrances.com
Description
Rev 8-10-16