GT1175 (H105 Medium) Hurricane Quick Set-Up and Parts Guide
P/N C-00106
Rocker Switch Settings (When wires M0 and M1 are switched to Red 7 the state is indicated by "ON"
Mode
Wire
Wire
M0
M1
Two Way
OFF
OFF
Mode
Hold Open
ON
ON
Mode
Reduced-Open
-
Mode
One-Way
ON
OFF
Traffic Mode
Night Traffic
OFF
ON
Mode
32 of 53
Wire
H
-
Both Sensors on Terminals 3 and 8 and the Holding Beam* on Terminal 4 will receive signals
while the door is closed or cycling.
-
No activation needed. Door is held open.
-
ON Door will go to the reduced opening position upon activation.
-
● Only the Sensor on Terminal 3 will receive signals while the door is closed.
● The Sensor on Terminal 8 and the Holding Beam on Terminal 4 will be ignored while the door
is closed.
● During the door cycle both the Sensors and the Holding Beam will receive signals.
● The electric lock will be active to prevent exterior entry.
-
● No Sensor on Terminals 3 or 8 or the Holding Beam on Terminal 4 will receive signals while
the door is closed.
● Activation is only accomplished by switching M0 to Red (7).
● During the door cycle both the sensors and the Holding Beam will receive signals. The
electric lock remains locked except for activations from wall plates or card readers.
Description
www.NabcoEntrances.com
Rev 8-10-16