IMO iDrive EDX 100V series 1-ph/0.2 – 0.75kW (0.25 – 1HP) Owner's Manual page 48

Ac micro-inverters for small 3-phase induction motors
Table of Contents

Advertisement

Advanced 'b' parameters functions
b00 Acceleration time 2 (s): 00.1 – 999
b01 Deceleration time 2 (s): 00.1 – 999
b02 V/F Slip Compensation Gain 00.0 – 100%
b03 Motor no-load current (A)
Motor no-load current differs with iDrive capacity b89. Adjust according to motor information.
b04: Output voltage ratio at max. frequency (%)
b05: Mid frequency (Hz)
b06: Output voltage ratio at mid. frequency (%)
b07: Min. output frequency (Hz)
b08: Output voltage ratio at min. frequency (%)
b04~b08 please refer to A07 description
b09 Motor rated current (A)
b10 Motor rated voltage (V)
b11 Motor rated base frequency (Hz)
b12 Motor rated power (kW)
b13 Motor rated speed (RPM)
b14 Torque Boost Gain (Only for V/F control, A06 = 001)
If motor load torque increases, this function increases the available output torque to match the load.
Te
=
Δ
(load current)
• Torque/Speed curve pattern:
Torque
C %
B %
A %
• Operating frequency range: 0 ~ Motor rated frequency
I
Gain
(torque boost)
Q
00.0 – 100%
00.1 – 200Hz
00.0 – 100%
00.1 – 200Hz
00.0 – 100%
ΔTe : Increase output torque capacity
RPM
4-13
Chapter 4 Software index

Advertisement

Table of Contents
loading

Table of Contents