IMO iDrive EDX 100V series 1-ph/0.2 – 0.75kW (0.25 – 1HP) Owner's Manual page 3

Ac micro-inverters for small 3-phase induction motors
Table of Contents

Advertisement

Step 3 - Check low speed motor rotation direction without
load from keypad.
(See keypad diagram on previous page)
Press
RUN/STOP
frequency output value. The display will now become solid (not blinking) because the
inverter output is ON.
Check the operating direction of the motor.
IF the direction of the motor is incorrect:
Press
RUN/STOP
off, change over motor connections T1 and T2 for example.
Apply the power again, and then check the motor direction by pressing
If rotation is correct press
Step 4 - Check full speed at 50Hz / 60Hz
Increase the frequency with
Set frequency to 50Hz / 60Hz according to the above.
Press
RUN/STOP
Press
RUN/STOP
Step 5 - Other settings
For other functions, please refer to iDrive EDX user manual.
Example:
Frequency Upper Limit (Hz)................................. P. 4-9
Frequency Lower Limit (Hz)..................................P. 4-9
Acceleration time (s)............................................ P. 4-10
Deceleration time (s)............................................ P. 4-10
Control mode (Vector, V/F)....................................P. 4-10
Motor rated current (A)........................................P. 4-13
Step 6 - Vector Mode Settings
If iDrive is required to run in Vector Mode (A06 = 001), the motor parameters need to be set.
The required data should found on the motor rating plate. (Motor kW = 0.75
The parameters to set for vector operation are:
Motor Rated Current (Amps) (b09)
Motor Rated Voltage (Volts) (b10)
Motor Rated Frequency (Hz) (b11)
Motor Rated Power (KW) (b12)
Motor Rated Speed (RPM) (b13)
Additional Vector Mode Settings to adjust for optimum performance are:
Torque boost gain (b14)
Slip compensation gain (b15)
Low Frequency Voltage Compensation (b16) See page 4-14
key. 7-segment display will indicates 00.0 to 05.0. This number is the
key, turn off the AC power supply. When the power indicator LED is
RUN/STOP
,
keys, press DATA/ENT to save this frequency.
key; check that the motor accelerates smoothly to full speed.
key; check that the motor decelerates smoothly to zero speed.
key again.
See page 4-13
See page 4-13
See page 4-13
See page 4-13
See page 4-13
See page 4-13
See page 4-14
ii
RUN/STOP
key.