During Operation; Operating Environment - IMO iDrive EDX 100V series 1-ph/0.2 – 0.75kW (0.25 – 1HP) Owner's Manual

Ac micro-inverters for small 3-phase induction motors
Table of Contents

Advertisement

1.1.5 During operation

Do not connect or disconnect the motor while iDrive is operating otherwise the inverter
and/or the disconnecting device may be damaged by the high level of switch-off current.
To avoid electric shock, do not remove the front cover when power is on.
After a power-loss (under-volt) trip occurs, the motor will restart automatically when power is restored
if auto-restart function is set. In this case, care must be taken while working with the machine.
Note: External Emergency stop must mechanically open and un-latch the power supply to the
iDrive without any chance of re-closing until required. It is not permitted to rely upon software
control for an emergency stop.
Do not touch heat-generating components such as heat sink and brake resistor.
The inverter can operate the motor from low speeds to very high speeds.
Verify the allowable speed ranges of the motor and the load before operation.
Note the settings related to the braking unit.
Do not check signals on circuit PCB while the inverter is running.
Allow a minimum of 5 minutes for iDrive to discharge after power down before attempting
to disassemble or checking the components within the drive.

1.1.6 Operating environment

iDrive can be used in a non-condensing atmosphere in temperature range from -10
o
+50
C and relative humidity of 95%, but the environment should be free from corrosive or
explosive gasses, condensation or conductive dust.
Danger
Danger
Caution
Caution
Caution
1-3
Chapter 1
Safety Precautions
o
C to