IMO iDrive EDX 100V series 1-ph/0.2 – 0.75kW (0.25 – 1HP) Owner's Manual page 29

Ac micro-inverters for small 3-phase induction motors
Table of Contents

Advertisement

3.6
Descriptions of iDrive Power and Control terminals
Power input, power output, and earth/ground terminal block descriptions
Terminal
L1(L)
Main power input Single-phase: L1/L3(N)
L2
L3(N)
DC link and braking module* connection terminals.
Never connect resistors directly to these terminals or damage will occur!
T1
Inverter output.
T2
Connect appropriate 3-phase AC induction motor to these terminals.
T3
PE
Earth / Ground terminals (2 points)
A brake module is required for applications where a load with high inertia needs to be stopped
*
rapidly.
Use a correctly rated braking module and resistor(s) to dissipate the energy generated by the load
during stopping or rapid speed change for example otherwise iDrive may trip on over-voltage 'OV'.
Chapter 3 Environment description and installation
Description
Three-phase: L1/L2/L3
3-19