IMO iDrive EDX 100V series 1-ph/0.2 – 0.75kW (0.25 – 1HP) Owner's Manual page 28

Ac micro-inverters for small 3-phase induction motors
Table of Contents

Advertisement

3.5 iDrive EDX connection diagram
Power terminals
Single phase 100~120V
1/3 phase 200~240V
3 phase 380~480V
PNP common terminal
Multi-function
digital input
'x'
terminals
12/24Vdc
NPN common terminal
Multi-function analog
input terminal
10kΩ
Set Frequency
PID feed back input
Note 1:- Connect point 'x' to either: -
Terminal (3) (internal +24Vdc) for PNP mode (positive switching)
(3) 24V
OR...
Terminal (8) (Common 0V) for NPN mode (negative switching).
(4)S1, (5)S2, (6)S3, (7)S4
Note2:- External 24Vdc may be used to supply the external contacts at point 'x'.
If so then connect the 0V of the external supply to Common (terminal 8).
Optional brake module for
braking high-inertia loads.
Requires suitable resistor.
L1(L)
L2
L3(N)
PE
(3) 24V
(4) S1
(5) S2
(6) S3
(7) S4
(8) COM
(9) 10V
(10) AIN
(11) COM
FM
(12) FM+
Chapter 3 Environment description and installation
Braking
Module
T1
T2
T3
PE
RA (1)
RB (2)
S5
S6
T+
T-
24V/0.6A
(4)S1, (5)S2, (6)S3, (7)S4
3-18
Optional braking
resistor
Motor
Multi-function digital output relay
SW1: Digital signal selector NPN / PNP
(UP = NPN / DOWN = PNP)
SW2: Control signal selector switch
(UP = 0~10Vdc / DOWN = 4~20mA)
Optional interface
Multi-function input
output card
(2 IN/ 1 OUT)
Remote keypad
(8)COM

Advertisement

Table of Contents
loading

Table of Contents