IMO iDrive EDX 100V series 1-ph/0.2 – 0.75kW (0.25 – 1HP) Owner's Manual page 13

Ac micro-inverters for small 3-phase induction motors
Table of Contents

Advertisement

• iDrive EDX- 040-21 / 075-21; 040-11 / 075-11-N4S (IP65
(PE)
100~120V
OR
200~240VAC
(PE)
50/60Hz
Fuses /
fuse/link or
MCB type
circuit
protection
AC
100~120V
or
200~240V
50/60HZ
TM2
NOTES A :
1. Isolating switch, REV-0-FWD switch and potentiometer are only
for EDX-######- N4S models
2. Power supply cable : 600V AC rated PVC
3. Motor cable : 600V AC rated PVC / (screened or armoured)/PVC
4. Maximum torque on terminal screws :
(1). Power/motor cable (plug in) terminal : 5kg-cm(4.34 in-lb)
(2). Remote control wire : 4kg-cm (3.47 in-lb)
(3). Outer cover (M4) : 6kg-cm (5.20 in-lb)
Isolator
T1
L1
T2
L2
T3
(PE)
(PE)
REV-0-FWD
Switch
S2
24V
S1
Potentiometer
10V
AIN
COM
Chapter 3 Environment description and installation
123.4 mm (4.86")
NOTES B:
(1). Input power : single-phase (L1,L2,
ensuring supply is 100~120 or 200~240VAC
according to model type.
(2). Motor output: three-phase (T1,T2,T3,
3
PHASE
Caution: Do not start or stop the motor
M
by switching input power
‧For EV-######-N4S type :
Ensure that the REV-0-FWD switch is set at '0'
position so that the iDrive has no run signal
at power-on otherwise injury may
result.
3-3
type installation:
)
(PE))
(PE) ).

Advertisement

Table of Contents
loading

Table of Contents