Advertisement

Installation
Connection to the left- or right-hand side of the machine
1.
2.
3.
Use a spirit level to check that the sinks are horizontal and adjust the height, if
necessary.
3
A - A
Water connection
Electrical connection
Floor drain
Attach the sink connection to the machine and then adjust.
Drill two ø 4.5 mm holes through the sink connection and the machine, ap-
prox. 100 mm from each outer edge.
Countersink the holes.
Seal with silicone between the connection and the machine.
Secure the sink with countersunk M4 screws, grommets on the outside sur-
face and nuts. Alternatively, you can secure the sink to the wall with wall
brackets.
WD-6C
2
300730_C_R2b
10
Rev. 3.0 (201305)