Prepare the program to execute and operate like explained in "Running a program" paragraph. The
control will ask if you want to make the crop cut or no. When it will displayed the message, press
YES to make a crop cut or NO to start directly with the first cutting length.

12.3.1 How to reset the automatic workstop sensor

If the first cut is too short or too long, then it is required to reset the automatic workstop sensor. To
do so:
Press the SET button
Press the button
123456
Enter the password and press OK
Parameter 13 gives the distance between the sensor and the blade. If the cut is too short,
reduce the set value of the difference in length (i.e. if 298 instead of 300, reduce the set
value by 2 mm). If the cut is to long, increase the set value of the difference in length.
Exit the parameter area by pressing OK, then EXIT

12.4. BAND DEVIATION MONITOR (OPTION)

To set the band deviation monitor:
Press the SET button
Press the button
123456
Enter the password and press OK
Set the parameter #14 "Max deviation" to the desired value
Exit the parameter area by pressing OK, then EXIT
L
OADING THE MATERIAL ONTO THE MACHINE
Moving bars, especially if they are in bundles, it is necessary to pay attention to the secu-
rity rules for the movement of heavy loads.
Keep the bundle with steel strips until it is in the vises, then remove the strap before start-
ing the cutting cycle.