Changing The Air And Fluid Nozzles - Krautzberger RA 5 Operating Instruction

Automatic spray gun
Hide thumbs Also See for RA 5:
Table of Contents

Advertisement

7.3

Changing the air and fluid nozzles

Removing the nozzles
Fig. 12: Removing the nozzles
1.
Loosen the knurled nut ( Fig. 124).
2.
Remove the air nozzle ( Fig. 12/3).
3.
Unscrew the fluid nozzle ( Fig. 12/2) with a flat spanner.
Always change the fluid nozzle and needle together (
fluid needle' on page 31).
Attaching the nozzles
1.
The air distributor ring ( Fig. 12/1) is only required for flat jet nozzles. When fitting the
device with round or flat jet nozzles, the air distributor ring ( Fig. 12/1) is not mounted,
but it is included in the scope of delivery.
If necessary, make sure that the air distributor ring ( Fig. 12/1) is positioned correctly.
2.
Screw on the fluid nozzle ( Fig. 12/2) with a flat spanner.
3.
Attach the air nozzle ( Fig. 12/3) and tighten it with the knurled nut ( Fig. 12/4).
GB–30
Operating instructions
T-Dok-449-GB-Rev.4
Ä Chapter 7.4 'Changing the
mail@krautzberger.com, www.krautzberger.com