Connection Scheme; Preliminary Air Control - Krautzberger RA 5 Operating Instruction

Automatic spray gun
Hide thumbs Also See for RA 5:
Table of Contents

Advertisement

Automatic spray gun RA 5
5.7

Connection scheme

Fig. 9: Connection scheme
1
Compressed-air port
2
Ball cock
3
Oil- /water separator
4
Compressed air regulator round jet
4.1
Solenoid valve round jet ON
5
Pressure jet regulator flat jet
5.1
Solenoid valve flat jet air ON
6
Solenoid valve ON
7
Solenoid valve OFF
8
Pump
5.8

Preliminary air control

Absolutely adhere to the preliminary air control "F" and "R" according to the scheme. Otherwise,
fluid can escape unatomised from the fluid nozzle at the beginning of the spraying procedure and
when ending the spray procedure, the nozzles can be soiled or blocked.
200-0319 ■ 200-0321 ■ 200-0323 ■ 200-0324
9
Back pressure regulators
10
Container
F
Flat jet air
R
Round jet air
ST A Open control air
ST Z Close control air (double controller,
optional)
M
Fluid connection
M
Circulation connection (optional)
ENGLISH