Changing The Material Nozzle And The Air Nozzle - Krautzberger MC1 Operating Instructions Manual

Automatic spray gun
Table of Contents

Advertisement

8.4

Changing the material nozzle and the air nozzle

Removing the nozzles
1.
Clean the automatic spray gun (
Fig. 4: Removing the nozzles
2.
Unscrew the cap nut with air nozzle ( Fig. 4/4).
3.
Unscrew the material nozzle ( Fig. 4/3), composed of the cannula ( Fig. 4/1) and the seal (
Fig. 4/2), from the main element.
4.
Unscrew the material nozzle and seal from the cannula.
5.
Check the seal for damage and replace it if necessary.
Attaching the nozzles
1.
WARNING!
Risk of injury through the use of incorrect spare parts!
Screw the new material nozzle ( Fig. 4/3) and the seal ( Fig. 4/2) back onto the cannula (
Fig. 4/1).
2.
Insert the mounted cannula back into the main element.
3.
Tighten the new air nozzle with the cap nut ( Fig. 4/4) again.
GB–26
Operating instructions
Ä Chapter 8.3 'Cleaning' on page 25).
T-Dok-689-GB-Rev.1
mail@krautzberger.com, www.krautzberger.com

Advertisement

Table of Contents
loading

Table of Contents