Automatic spray gun RA 5
5.4

Changing the main elements

5.4.1 Plugged-in design
Removing the main elements
Fig. 5: Removing the main elements
1.
Turn the lever ( Fig. 5/3) to the unlocking position.
The unlocking and locking positions are indicated by the symbols
2.
Press the lever ( Fig. 5/3) in and pull the main element ( Fig. 5/1) off the adapter ( Fig. 5/4).
Mounting the main elements
1.
Turn the lever ( Fig. 5/3) to the unlocking position.
2.
Insert the main element ( Fig. 5/1) with the clamp bolts ( Fig. 5/2) into the adapter ( Fig. 5/4)
and let them snap in.
3.
Turn the lever ( Fig. 5/3) to the locking position.
200-0319 ■ 200-0321 ■ 200-0323 ■ 200-0324
ENGLISH
and .