U
Set-up clearance:
Setup clearance to the measuring point that the TNC
should maintain during pre-positioning. Input range 0
to 99999.9999
U
Tolerance:
Maximum permissible deviation between nominal
and actual position of the respective test points. Input
range 0 to 99999.999. If the test point is out of
tolerance, the TNC issues an error message
U
Tool number/tool name:
Tool number (or name) of the touch probe. Input
range 0 to 30000.9 if a number is entered; maximum
16 characters if a name is entered. If entering a tool
name, enter it between single quotation marks
U
Confirm the entries: The TNC generates the test
program, shows the name of the test program in a
pop-up window and asks whether you want to run the
test program
U
Answer with NO if you want to run the test program
later, and with YES if you want to run it now
U
If you have confirmed with YES, the TNC changes to
the Full Sequence mode and automatically selects
the generated program
U
Start the test program: The TNC prompts you to
manually pre-position the touch probe so that it is
located at clearance height. Follow the instructions in
the pop-up window
U
Start the measuring process: The TNC moves to each
test point one after the other. With a soft key you
specify the positioning strategy. Conform with NC
start each time
U
At the end of the test program the TNC displays a pop-
up window with the deviations from the nominal
position. If a test point is out of tolerance, the TNC
issues an error message in the pop-up window