Machine With Built-In Aktivclean Water Softening Device - Meiko FV 40.2 Operating Instructions Manual

Table of Contents

Advertisement

Care and Maintenance
Operating instructions
FV 40.2
5
The cleanliness of final rinse nozzles must be checked weekly and if
necessary clean under running water.
The inserts for final rinse nozzles must be inserted with the prongs facing the
direction of the water flow.
4.5
Maintenance of stainless steel surfaces
The appliance is made of high-quality stainless steel. Nevertheless, under
certain conditions corrosion may appear.
To maintain stainless steel surfaces permanently free from corrosion
use only cleaning products which are properly suited.
Use only products which do not attack the material, build up a film or cause
discoloration.
4.6
De-scaling
If the appliance is operated with hard water, scale can build up in the boiler and
wash tank, making it necessary to de-scale the tank interior, the tank heating
equipment, the boiler heating equipment, the items to be washed.
Use only products suitable for industrial dishwashing machines to de-scale the
appliance. When using these products please observe the manufacturer's
instructions.
After de-scaling:
Flush the de-scaling product completely out of the appliance. 1 or 2 rinse
cycles with fresh water are necessary to achieve this.
Even small amounts of de-scaling product remaining in the appliance may
cause plastic components and sealing materials to deteriorate.
If the appliance is heavily scaled, you should ask a service engineer from the
agency responsible to de-scale the boiler.
Machine with built-in AktivClean water softening
device.
5.1
General
The built-in ActivClean water softening device operates automatically. All that is
necessary is to replenish the salt from time to time. The regeneration water is
fed directly into the drain. It is not necessary to drain the tank during the
regeneration process.
The temperature of the feed water must not exceed 50° C.
5.2
Adjustment of water hardness
The water softening device is pre-set to 30°Gh in the factory. When the service
engineer installs or commissions the appliance he should adjust this value
depending on the actual water hardness. Should there be any further changes
in the water hardness, this parameter must be adjusted accordingly as set out
in the Short Programming Instructions.
- 6 -