General safety information
Operating instructions
FV 40.2
Ø
Danger of burning: indicates possible hazard due to hot surfaces or
media.
Danger of crushing: indicates hazard caused by moving parts of the
appliance.
Note: includes important additional information for the operator
regarding the system or parts of the system and offers further
information.
Instruction symbol: placed in front of text requiring an action.
3.2
Operating conditions
It is taken for granted that the planning of the system, its installation,
commissioning and maintenance are executed by properly instructed
staff and that these works are checked by responsible specialists. The
indications on the name plate of the machine must correspond to the
technical sheet and the local connection conditions.
Conditions to be provided by the customer:
q Frost free storage and installation area
q Electrical connection in accordance with the technical sheet
q Fresh water connection in accordance with the technical sheet
q Waste water connection in accordance with the technical sheet
3.2.1 Requirements for the installation area
Ø Ensure that the storage and installation area is permanently frost
free.
The machine is only frost-resistant in the state it is delivered or when
provided with special features (option: frost drainage). If the appliance is
installed in an area where the surrounding temperatures are below
freezing point, damage can occur to components containing water, such
as pump, solenoid valve, boiler, etc.
3.2.2 Requirements for the electrical connection
The electrical connection of the machine must only be made by a
specialist as defined in DIN EN 50110-1.
The customer must guarantee the following with regard to the
connection:
Ø The correct voltage and type of current must be available.
Ø Mains supply lines must be protected according to regulations and
provided with a main switch.
Ø Appliances must have a fixed connection and equi-potential bonding.
Ø If an unearthed neutral (N) is used with three-phase current the main
switch must have 4-poles, and 2-poles if alternating current is used.
Ø When connecting to three-phase current, a 5-pole terminal strip (L1,
L2, L3, N, PE) must be used, but for connection to alternating current
a 3-pole terminal strip (L1, N, PE) must be used.