What can be done by the setting tool
Indicator/Input & Output Setting

Auxiliary Output (Non-Safety Output)

 Overview
Auxiliary outputs 1 and 2 can be changed.
Do not use auxiliary output or external indicator output for safety applications. Failure of
these outputs may result in serious injury.
 Example
•To assign lockout output or warning zone output to auxiliary output
•To blink an external indicator connected to auxiliary output
 Functional Description
• Auxiliary Output (Non-Safety Output)
Chapter 2 Basic System Auxiliary Output (Non-Safety Output) p.32
• Output Operation Mode
Select output detail from auxiliary output.
• Reverse Output Mode
Reverses auxiliary output logic.
• Lighting-Up Pattern
Configures lighting-up/blinking pattern when connecting an indicator to auxiliary output.
• Auxiliary Output Diagnosis Function
Enabling auxiliary output diagnosis allows breakage*1 and short circuit detection*2 of auxiliary output
1.
Use incandescent lamp if you want to use an indicator connected to auxiliary output 1 and enable the
diagnosis function.
Breakage detection: When there is breakage of auxiliary output 1, F3SJ is transitioned to lockout.
*1
Short circuit detection:When there is short-circuit of auxiliary output 1, F3SJ is transitioned to
*2
lockout.
- If output operation mode and reverse output mode are used for other than initial setting, do not short-circuit by
auxiliary output and external device monitoring input. When external device monitoring function is not used, disable
the external device monitoring function.
-
For auxiliary output 1 and 2, load current must be 300mA or less and 50mA or less respectively.
F3SJ-A
94
User's Manual
External Device Monitoring Function p.101