Omron F3SJ Series Original Instructions Manual page 80

Safety light curtain
Table of Contents

Advertisement

What can be done by the setting tool
Shown below is an example of description in Chapter 3, taking "External Device Monitoring" for
instance.
Ex. "External Device Monitoring Function"
(1)
(2)
(3)
(4)
(5)
(6)
(1) Describes function's name.
(2) Indicates what can be done by the setting tool.
(3) Describes detailed usage of the function.
(4) Describes detailed explanation of the function.
(5) Indicates setup items available for the setting tool.
(6) Illustrates figures and time charts.
F3SJ-A
60
User's Manual
Changing Setting of Functions
External Device Monitoring Function
Overview
Settings for external device monitoring can be changed.
Example
•To adjust allowable delay time to a device's response time
Functional Description
• External Device Monitoring Function
(Chapter 2)External Device Monitoring Function (EDM)
• Allowable Delay Time
Specifies maximum value T1 of external device's operation time after safety output changes.
Lockout state occurs if the external device monitoring input does not change when the time exceeds
this maximum value.
External device input information can be provided to auxiliary output or external indicator output.
- Auxiliary Output (Non-Safety Output)
- External Indicator Output (Non-Safety Output)
Setting Change
Function
Initial Setting
External Device Monitoring
Enabled
Function
Allowable Delay Time
0.3s
Unblocked
F3SJ Unblocked/Blocked
Blocked
ON
Safety output
OFF
External device
ON
monitoring input
OFF
Available Setup Item
Setting Console
Enable/disable
0.1 to 2.5s (by 0.1s)
T1
T1
Lockout
PC Setting Tool

Advertisement

Table of Contents