Designated Beam Output Function - Omron F3SJ Series Original Instructions Manual

Safety light curtain
Table of Contents

Advertisement

What can be done by the setting tool
Beams for which output does not turn ON when interrupted, such as fixed or floating blanking beams,
*1
are excluded. Evaluation is not performed during overriding as well.
Fixed blanking or floating blanking beam setting is required.
*2
Designated beam setting is required.
*3
Warning Zone beam setting is required.
*4
ON state is kept until the sensor is reset by power cycle or the reset input.
*5
- Fixed Blanking Function p.66
- Floating Blanking Function p.70
- Designated Beam Output Function p.96
- Warning Zone Function p.77
If "designated beam output information" is assigned for output operation mode of auxiliary outputs 1 or 2 or external
indicator outputs 1 or 2, these cannot be assigned to other output operation.

Designated Beam Output Function

 Overview
Incidence/interruption information of a given beam can be output. This function is for the PC tool for
F3SJ only.
 Example
•To turn an external indicator ON when a specified beam of F3SJ is interrupted
•To provide an auxiliary output when a specified beam of F3SJ is receiving light
 Functional Description
• Designated Beam Output Function
If one or more specified beams are interrupted or receiving light, the state of interruption/reception can
be provided as an auxiliary output or an external indicator output operation.
Note that a designated beam output must be assigned to an output operation mode.
- Auxiliary Output (Non-Safety Output) p.94
- External Indicator Output (Non-Safety Output) p.98
• Designated Beam Zone Setting
Use this setting to set the beams to use as designated beams.
With an interrupting object in the appropriate position, it is possible to perform teaching and designate
beams manually.
• Designated Beam Incidence State
Specifies output status of a designated beam whether it is receiving light or interrupted.
ON when interrupted: Output turns ON if one or more beams are interrupted.
ON when receiving: Output turns ON if one or more beams are receiving light.