Omron F3SJ Series Original Instructions Manual page 201

Safety light curtain
Table of Contents

Advertisement

ON
Blink
Emitter
Receiver
Error code
10, 11
C
C
B
B
A
A
19, *2
C
C
B
B
A
A
20
C
C
B
B
A
A
30, 31, 32,
C
C
37, 39
B
B
A
A
OFF
Error Description
Mutual
Disturbance light is received.
interference error
The receiver is receiving light
emitted from another photoelectric
switch or F3SJ.
Power supply
Power supply voltage is outside
capacity error
the rated range.
Voltage fluctuation due to
insufficient power supply capacity.
Instantaneous break or
instantaneous stop due to power
sharing with other devices.
Blanking
A fixed blanking beam other than
monitoring error
allowable beams received light.
Number of interrupted beams is
less than (number of floating
blanking beams - number of
allowable beams).
Communication
The communication line or other
error
wiring is broken or short-circuited.
Communication error due to
noise.
If the wiring is extended without
using the exclusive cord (F39-
JC), no cord with the same
performance or more than the
exclusive cord is used.
A power cable or series
connection cable connector is
detached. If not, a contact failure
due to the loose connector, the
intrusion of liquid (oil etc.) into the
connector, or the attachment of a
foreign material has occurred.
Cause
Block the disturbance light.
p.118
See Chapter 4 "Mutual
Interference Prevention".
p.117
Connect to a 24VDC± 20% power
supply voltage.
Replace the power supply with
one that has a larger capacity.
Do not share the power supply
with other devices, and connect to
a power supply that is dedicated
to devices for electrical-detection
protective functions, such as the
F3SJ, safety controller, muting
sensor, etc.
Adjust a position of the device so
that a fixed blanking beam other
than allowable beam should not
receiver light. Or, configure fixed
blanking setting again.
p.66
Set number of floating blanking
beams and number of allowable
beams based on a size of
interrupting object.
p.70
Check the wiring and cables.
Check the noise level in the
environment around the
communication line. The inductive
noise tends to be induced
especially if the signal line and the
power line are arranged in
parallel. Be sure to lay the power
line away from the signal line.
Use a cord (twisted-pair cable)
with the same performance or
more than the exclusive cord
(F39-JC). Otherwise connect
the shield to the 0V line.
Check connectors of power cable
and series-connection cables.
After cleaning the inside of the
cap (if any foreign material is
attached), tighten the cap more
closely. Replace the cap if any
liquid such as oil has intruded.
Appendix
Solution
F3SJ-A
181
User's Manual
E

Advertisement

Table of Contents
loading