Omron F3SJ Series Original Instructions Manual page 160

Safety light curtain
Table of Contents

Advertisement

Wiring/Installation
•When replacing F3SN-N25 with F3SJ-AN25
Model name
F3SN-0187N25
F3SN-0217N25
F3SN-0232N25
F3SN-0247N25
F3SN-0262N25
For lengths greater than the F3SN-0277N25:
Subtract a number, ranging from 7 to 22, from the F3SN's 4-digit number and apply it as the F3SJ's 4-
digit number, and then replace with the standard brackets included with the product.
[Selection example] F3SN-A0322N25 becomes F3SJ-A0300N25 (replace with standard brackets)
The formula shown above is recommended for mounting in the center of a mounting hole. If a
mounting position is unmatched, another mounting hole must be drilled.
- The protective height becomes shorter by 7 to 22mm.
- Replace with outward-facing mounting of F39-LJ5 when you want to set the detection surface height to be same as
the F3SN.
However, the F39-LJ5 and intermediate mounting brackets cannot be mounted simultaneously, so set the protective
height to 600mm or less.
F3SJ-A
140
User's Manual
F3SN
Protective height
187
-
217
F3SJ-A0260N25
232
F3SJ-A0260N25
247
F3SJ-A0260N25
262
F3SJ-A0260N25
Replacement F3SJ
Model name
Protective height
-
260
260
260
260
Replacement method
using F39-LJ5
-
Inward-facing mounting
Inward + outward-facing
mounting
Inward + outward-facing
mounting
Outward-facing mounting

Advertisement

Table of Contents
loading

Table of Contents