Error Messages Output In Event Logs - HP XP User Manual

Storage adapter for microsoft volume shadowcopy
Table of Contents

Advertisement

Message
Another version of this product is already installed. Installation of this version cannot continue.
To configure or remove the existing version of this product, use Add/Remove Programs on the
Control Panel,
Explanation
VSS Provider of a different version has been installed.
Recommended action
Update installation from an installer is not supported. Execute update installation according to
the procedures in Chapter 5.

Error messages output in event logs

Note: If there are no errors or alert event IDs detected by event logs in Table 8.3.2-1, take action
against back-dated errors and alert event IDs.
5001
Type
Error
Message
The VSS Hardware Provider was unable to load Error# [Error number]
Explanation
Cannot load VSS Provider.
Recommended action
(1) Execute repair install. (See Chapter 6).
(2) Execute new installation (See Section 3.1) once after having uninstalled. (See Chapter
4).
5004
Type
Error
Message
Failed to create V-VOL [LU number of V-VOL] for P-VOL [LU number of P-VOL], Error# [Error
number]
Explanation
Cannot create V-VOL for P-VOL.
Recommended action
An error occurred when an operation command was given to a disk array system.
See
"About errors attributable to disk array systems" (page
5006
Type
Error
133).
Error messages
75

Advertisement

Table of Contents
loading

Table of Contents