E2002060 - HP XP User Manual

Storage adapter for microsoft volume shadowcopy
Table of Contents

Advertisement

E2002060

Message
ResyncLuns is not supported for the storage Serial Number 'Serial number' SourceLun[LU#]
-->TargetLuns[LU#]
Explanation
ResyncLuns IF is unsupported.
Recommended action
When the disk array system is in the XP P9500/XP7, ResyncLuns IF is unsupported.
E2002064
Message
Stop the resync Shadow Copy operation.
Explanation
Stop the restore processing.
Recommended action
An error occurred when an operation command was given to the disk array system.
See
"About errors attributable to disk array systems" (page
E2002065
Message
ResyncLuns failed for serial number ' serial number ', SourceLUN: [LU# of S-VOL] -->TargetLuns:
[LU# of P-VOL], with Error Code: [Error code].
Explanation
Resynchronization failed when restoring.
Recommended action
[XP P9500/XP7]
(1) Using Storage Management Software, confirm and perform the following operation:
When a pair status for restore is not PSUS, restore operation cannot be performed. Using
Storage Management Software, make the pair status PSUS.
[XP7]
In the case of the HA configuration, if the HA pair status to be restored is not PSUS, restore
operation cannot be performed. Change the HA pair status to PSPU using the storage
management software.
(2) An error occurred when an operation command was given to the disk array system.
See
"About errors attributable to disk array systems" (page
E2002066
Message
SplitAllPairs: Business Copy pair split failed. Error Code: [Error code] - P-Vol: [LU# of P-VOL]
S-Vol: [LU# of S-VOL].
122 Troubleshooting
133).
133).

Advertisement

Table of Contents
loading