E200204A - HP XP User Manual

Storage adapter for microsoft volume shadowcopy
Table of Contents

Advertisement

Explanation
Recommended action
(1) Another interrupted S-VOL creation, and P-VOL or S-VOL might have been deleted.
Confirm the existence of P-VOL and S-VOL and check the pair status using Storage
Management Software.
(2) An error occurred when an operation command was given to the disk array system.
See
"About errors attributable to disk array systems" (page

E200204A

Message
Creating P-Vol S-Vol pair failed.
Explanation
Creation of a P-VOL/S-VOL pair failed.
Recommended action
(1) There are one or more volumes with the status of "Split Pending/Paired Internally
Synchronizing" under the specified P-VOL. Confirm the pair status using Storage Management
Software and re-execute after waiting until the above status is removed.
(2) An error occurred when an operation command was given to the disk array system.
See
"About errors attributable to disk array systems" (page
E200204B
Message
Generic failure.
Explanation
Processing failed.
Recommended action
Reference the VSS Provider log files and other Error messages, and take the corresponding
action.
E200204C
Message
LU mapping mode is disabled, Serial Number: [serial number].
Explanation
The LU mapping mode is disabled.
Recommended action
Enable LU mapping mode using Storage Management Software.
E200204E
Message
Pair resting status PSUS is not supported for the P-Vol LU: [LU# of P-VOL].
133).
133).
Error messages