E20020D6

Message
Creation of S-Vol failed: The specified LU is in regressed status.
Explanation
Creation of an S-VOL failed.
Recommended action
A failure occurred in the specified RAID/Parity group. Fix the failure and re-execute.
E20020DB
Message
No FC host groups or iSCSI targets are configured for the local server.
Explanation
No host groups are set in the S-VOL/V-VOL server.
Recommended action
(1) In the FC environment, create a host group registering WWW of the imported server.
Also, confirm that HBA has been recognized correctly.
WWN of the import server can be specified in the configuration file. If the error has not been
resolved even if the environment was revised, see Table 2.5.2-1 "Specifying WWN of the
import server from the configuration file" to specify WWN of the import server in the
configuration file and check that the error is solved.
(2) In the iSCSI environment, start Microsoft iSCSI Initiator Service from Service in
Management tool.
(3) See Subsection 2.3.2 and confirm that the server configuration has been supported.
(4) In case of using the VMware Guest to Guest Backup (FC) function, confirm whether
WWN of ESXi has been specified in the configuration file.
(See Table 3.2.1-2)
E20020DC
Message
Shadow copy LU[[LU# of S-VOL/V-VOL]] is not mapped to a valid port.
Explanation
Because S-VOL/V-VOL is not mapped, importing failed.
Recommended action
[XP P9500/XP7]
(1) Confirm whether the problem is due to an interruption by another application. See Table
2.5.2 -1.
(2) Perform the following operation using Storage Management Software.
[XP P9500/XP7]
After mapping the target S-VOL to the Host group with the name HP-VSS-HG, perform resync
processing. In addition, when a host group does not exist, create HP-VSS-HG and perform a
similar procedure.
126 Troubleshooting