E2002014 - HP XP User Manual

Storage adapter for microsoft volume shadowcopy
Table of Contents

Advertisement

Recommended action
(1) Confirm the IP address of the disk array system using Storage Management Software,
and type the correct IP address into the Add Storage dialog box.
(2) If authentication is enabled for the disk array system, confirm the user name and password
and type them into the Add Storage dialog box.
(3) Confirm that the setup file is not open.

E2002014

Message
LoadListLocalP-Vol failed.
Explanation
Failed to update the P-VOL list.
Recommended action
(1) Using Storage Management Software, confirm the valid/invalid setting of the Business
Copy function. If it is invalid, change it to valid.
(2) An error occurred when an operation command was given to the disk array system.
See
"About errors attributable to disk array systems" (page
E2002015
Message
Unable to get LU object for LUN: [serial number:LU number of P-VOL].
Explanation
Could not get LU number information for the P-VOL.
Recommended action
(1) Confirm whether the P-VOL exists in a disk array system using Storage Management
Software.
(2) An error occurred when an operation command was given to the disk array system.
See
"About errors attributable to disk array systems" (page
E2002017
Message
S-Vol cannot be created for this volume. P-Vol is associated with Snapshot V-Vol.
Explanation
Creation of S-VOL failed. P-VOL is paired with a V-VOL.
Recommended action
Create S-VOL after deleting the V-VOL which is associated with the specified P-VOL.
E2002018
Message
Error: Business Copy cannot be created for this volume.
106 Troubleshooting