E2002024 - HP XP User Manual

Storage adapter for microsoft volume shadowcopy
Table of Contents

Advertisement

(7) In the case of the Ext Stor configuration or HA configuration, do not describe
HORCM_VCMD in the HORCM CONF configuration file.
(8) Confirm that the HORCM CONF configuration file has not been used except for the
purpose of VSS Provider.

E2002024

Message
Unable to find and connect to any storage. Verify the controller IP address and/or XP P9500/XP7
Serial number and user credentials. Verify network connectivity. For XP P9500/XP7, check that
RAID Manager is active.
Explanation
There is no disk array system corresponding to the serial number (for a XP P9500/XP7 controller)
specified in the setup file. Or, the disk array system cannot be connected to.
Recommended action
[XP P9500/XP7]
(1) Confirm the serial number of the disk array system using Storage Management Software
and enter the proper serial number in the setup file. (See Subsection 3.2.1)
(2) Confirm that the instance of RAID Manager specified with the hiRaidcomX configuration
file is started.
(3) Confirm that the hiRaidcomX configuration file has been saved in the single-byte
alphanumeric characters (SJIS etc).
E2002025
Message
Configuration file not found.
Explanation
Cannot find the setup file.
Recommended action
Confirm that the setup file is stored in the installation folder of VSS Provider. If the configuration
file does not exist, create a configuration file and save it in the installation folder (See Subsection
3.2.1).
E2002026
Message
Configuration file does not have any valid Serial Number or IP Addresses.
Explanation
The setup file does not contain proper serial numbers or IP addresses in the correct format.
Recommended action
[XP P9500/XP7]
Confirm the serial number of the disk array system using Storage Management Software. Then,
type the proper serial number, user name, and password in the Add Storage dialog box, and
register the disk array system.