Programming Block Diagram - Sheet 2 - Parker 590 series Product Manual

Dc digital converter
Hide thumbs Also See for 590 series:
Table of Contents

Advertisement

590 Series DC Digital Converter
DIAMETER CALC.
DIAMETER [427] – 0.00%
MOD OF LINE SPEED [428] – 0.00%
MOD OF REEL SPEED [429] – 0.00%
UNFILTERED DIAMETER [430] – 0.00%
0.00 % – [424] LINE SPEED
0.00 % – [437] REEL SPEED
10.00 % – [425] MIN DIAMETER
5.00 % – [426] MIN SPEED
10.00 % – [462] RESET VALUE
DISABLED – [463] EXTERNAL RESET
5.0 SECS – [453] RAMP RATE
0.000 SECS – [401] DERIVATIVE TC
SETPOINT SUM 2
SPT. SUM 2 [451] – 0.00%
0.00 % – [444] INPUT 0
1.0000 – [447] RATIO 0
1.0000 – [448] DIVIDER 0
0.00 % – [443] INPUT 1
1.0000 – [446] RATIO 1
1.0000 – [466] DIVIDER 1
0.00 % – [445] INPUT 2
100.00 % – [449] LIMIT
0.100 SECS – [403] FILTER T.C.
OUTPUT 0 [491] –
OUTPUT 1 [492] –
miniLINK
0.00 % – [339] VALUE 1
0.00 % – [340] VALUE 2
0.00 % – [341] VALUE 3
0.00 % – [342] VALUE 4
0.00 % – [343] VALUE 5
0.00 % – [344] VALUE 6
0.00 % – [345] VALUE 7
0.00 % – [379] VALUE 8
0.00 % – [380] VALUE 9
0.00 % – [381] VALUE 10
0.00 % – [382] VALUE 11
0.00 % – [383] VALUE 12
0.00 % – [384] VALUE 13
0.00 % – [385] VALUE 14
OFF – [346] LOGIC 1
OFF – [347] LOGIC 2
OFF – [348] LOGIC 3
OFF – [349] LOGIC 4
OFF – [350] LOGIC 5
OFF – [351] LOGIC 6
OFF – [352] LOGIC 7
OFF – [353] LOGIC 8
TAPER CALC.
TAPERED DEMAND [452] – 0.00%
– TOT. TENS DEMAND [441] – 0.00%
0.00 % – [438] TAPER
0.00 % – [487] STATIC COMP
0.00 % – [439] TENSION SPT.
0.00 % – [488] DYNAMIC COMP
0.00 % – [440] TENSION TRIM
ENABLED – [489] REWIND
0.00 % – [479] FIX. INERTIA COMP –
PID
0.00 % – [480] VAR. INERTIA COMP –
PID OUTPUT [417] – 0.00%
100.00 % – [479] ROLL WIDTH/MASS –
PID CLAMPED [416] – FALSE
0.00 % – [498] LINE SPEED SPT
PID ERROR [415] – 0.00%
10 – [482] FILTER T.C.
1.0 – [404] PROP. GAIN
10 – [483] RATE CAL
5.00 SECS – [402] INT. TIME CONST.
0.00 % – [484] NORMALISED dv/dt
1.0000 – [486] TENSION SCALER
100.00% – [405] POSITIVE LIMIT
-100.00% – [406] NEGATIVE LIMIT
0.2000 – [407] O/P SCALER (TRIM) –
0.00% – [410] INPUT 1
0.00% – [411] INPUT 2
1.0000 – [412] RATIO 1
0.00 % – [432] TORQUE DEMAND
1.0000 – [413] RATIO 2
ENABLED – [433] TENSION ENABLE
1.0000 – [418] DIVIDER 1
ENABLED – [434] OVER WIND
1.0000 – [414] DIVIDER 2
ENABLED – [408] ENABLE
OFF – [409] INT. DEFEAT
0 – [473] MODE
20.00% – [474] MIN PROFILE GAIN –
PROFILED GAIN [475] – 0.0
0 – [390] INPUT
0 – [394] AUX INPUT
– 0
PNO 112
OFF – [392] ADVANCED
– 0
PNO 113
SWITCH – [393] MODE
– 0
PNO 114
– 0
PNO 115
– 0
PNO 116
– 0
PNO 117
– 0
PNO 118
0 – [395] INPUT
– 0
PNO 119
0 – [399] AUX INPUT
– 379 PNO 120
OFF – [397] ADVANCED
– 380 PNO 121
SWITCH – [398] MODE
– 381 PNO 122
– 382 PNO 123
– 383 PNO 124
– 384 PNO 125
– 385 PNO 126
ENABLED – [147] SRL LINK ENABLE
0 – [140] GROUP ID (GID)
– 0
PNO 127
0 – [141] UNIT ID (UID)
EI ASCII – [149] PROTOCOL
9600 – [151] BAUD RATE
DISABLED – [153] ESP SUP. (ASCII)
USER FILTER
0.00% – [145] CHANGEBAND (BIN) –
OUTPUT [296] – 0.00
0x00C0 – [150] ERROR REPORT
0.00 – [295] INPUT
0xFFFF – [148] PNO. 7
The Default Application
TENSION & COMP
TENS+COMP [478] –
INERTIA COMP [485] – 0.00%
TORQUE CALC.
POS. I CLAMP [435] – 0
NEG. I CLAMP [436] – 0
LINK 11
OUTPUT [391] – 0
LINK 12
OUTPUT [396] – 0
AUX PORT P2

Programming Block Diagram - Sheet 2

15-4

Advertisement

Table of Contents
loading

Table of Contents