Parker 590 series Product Manual page 110

Dc digital converter
Hide thumbs Also See for 590 series:
Table of Contents

Advertisement

6-20
Programming Your Application
PROGRAM STOP
State of program stop (Terminal B8). When B8 is at 24V, then PROGRAM STOP is FALSE
and the program stop front panel LED is also ON.
DRIVE START
Controller start/run command.
DRIVE ENABLE
Drive speed and current loop are enabled/quenched.
OPERATING MODE
Indicates whether the drive is in RUN, JOG 1....STOP etc.
FIELD ENABLE
Drive field loop is enabled/quenched.
FIELD DEMAND
Field current demand.
FIELD I FBK
Scaled field current feedback.
FLD.FIRING ANGLE
Field firing angle in degrees: 155 degrees is the value for back stop (min field) and 5 degrees is
the value for front stop (max field).
ANIN 1 (A2)
Speed setpoint no. 1.
ANIN 2 (A3)
Speed setpoint no. 2/current demand.
ANIN 3 (A4)
Speed setpoint no. 3 (ramped).
ANIN 4 (A5)
Negative current clamp; this is only active if bipolar clamps are enabled (C6 = ON).
ANIN 5 (A6)
Main current limit or positive current clamp if C6 = ON.
ANOUT 1 (A7)
Scaled speed feedback.
ANOUT 2 (A8)
Total speed setpoint.
START (C3)
Start/Run terminal.
DIGITAL INPUT (C4)
Jog/Take-up Slack terminal.
Tag No. 80 - D:17
(Refer to STOP RATES, page 6-57)
Tag No. 82 - D:18
(DIAGNOSTIC only)
Tag No. 84 - D:19
(DIAGNOSTIC only)
Tag No. 212 - D:20
(Refer to JOG/SLACK, page 6-32)
Tag No. 169 - D:21
(Refer to FIELD CONTROL, page 6-27)
Tag No. 183 - D:22
(Refer to FIELD CONTROL, page 6-27)
Tag No. 300 - D:23
(Refer to CALIBRATION, page 6-11)
Tag No. 184 - D:24
(Refer to FIELD CONTROL, page 6-27)
Tag No. 50 - D:25
(Refer to ANALOG INPUTS, page 6-5)
Tag No. 51 - D:26
(Refer to ANALOG INPUTS, page 6-5)
Tag No. 52 - D:27
(Refer to ANALOG INPUTS, page 6-5)
Tag No. 53 - D:28
(Refer to ANALOG INPUTS, page 6-5)
Tag No. 54 - D:29
(Refer to ANALOG INPUTS, page 6-5)
Tag No. 55 - D:30
(Refer to ANALOG OUTPUTS, page 6-7)
Tag No. 56 - D:31
(Refer to ANALOG OUTPUTS, page 6-7)
Tag No. 68 - D:32
(Refer to AUX I/O, page 6-8)
Tag No. 69 - D:33
(Refer to DIGITAL INPUTS, page 6-24 and AUX I/O, page 6-8)
TRUE/FALSE
ON/OFF
ENABLED/DISABLED
ENABLED/DISABLED
0.00% to 100.00%
-300.00% to 300.00%
0 DEG to 180 DEG
-100.00 to 100.00 VOLTS
-100.00 to 100.00 VOLTS
-100.00 to 100.00 VOLTS
-100.00 to 100.00 VOLTS
-100.00 to 100.00 VOLTS
-100.00 to 100.00 VOLTS
-100.00 to 100.00 VOLTS
ON/OFF
ON/OFF
590 Series DC Digital Converter

Advertisement

Table of Contents
loading