14-4
Serial Communications
Note: When printing this file, it is useful to select a proportionally-spaced text, such as Courier,
DIGITAL DC DRIVE
ISSUE:4.4
..MENU LEVEL
....DIAGNOSTICS
......SPEED DEMAND
[89 ] =
......SPEED FEEDBACK
[207 ] =
......SPEED ERROR
[297 ] =
......CURRENT DEMAND
[299 ] =
......CURRENT FEEDBACK [298 ] =
......POS. I CLAMP
[87 ] =
......NEG. I CLAMP
[88 ] =
......ACTUAL POS I LIM [67 ] =
......ACTUAL NEG I LIM [61 ] =
......INVERSE TIME O/P [203 ] =
......AT CURRENT LIMIT [42 ] = FALSE
......AT ZERO SPEED
[77 ] = TRUE
......AT ZERO SETPOINT [78 ] = TRUE
......AT STANDSTILL
[79 ] = TRUE
......STALL TRIP
[112 ] = OK
......RAMPING
[113 ] = FALSE
......PROGRAM STOP
[80 ] = TRUE
......DRIVE START
[82 ] = OFF
......DRIVE ENABLE
[84 ] = DISABLED
......OPERATING MODE
[212 ] = STOP
......FIELD ENABLE
[169 ] = DISABLED
......FIELD DEMAND
[183 ] =
......FIELD I FBK.
[300 ] =
......FLD.FIRING ANGLE [184 ] =
......ANIN 1 (A2)
[50 ] =
......ANIN 2 (A3)
[51 ] =
......ANIN 3 (A4)
[52 ] =
......ANIN 4 (A5)
[53 ] =
......ANIN 5 (A6)
[54 ] =
• The file ends in a ctrl-z. With some packages this automatically closes the downloaded file
but if this is not the case, when the Converter says it has finished and the host has stopped
scrolling text, close the file by hand. The last line should read :00000001FF
The file can now be treated like any normal file.
Download MMI (MMI DUMP -> P3)
This is the transfer of the MMI description from the Converter to a host computer. This
information fully documents the Converter's settings in a textual format that is clear and easy to
read.
• Connect the Converter to the host using the appropriate lead.
• Using a standard communications package prepare the host to receive an ASCII file.
Remember to set up the host's serial port first.
• Perform a PARAMETER SAVE of the Converter's settings. This ensures the Dump matches
the Converter's settings, (the listing is of the current settings, NOT the saved settings held in
EEprom).
• Set the P3 MODE parameter to DISABLE.
• Prepare the host PC to receive a file; use the file extension .MMI to differentiate it from
.UDP format files.
• Start downloading on the Converter by selecting DUMP MMI -> P3 on the MMI and
pressing the UP (↑) key, as instructed.
• The file ends in a ctrl-z. With some packages this automatically closes the file but if this is
not the case, when the Converter says it has finished and the host has stopped scrolling text,
close the file by hand.
• The file can now be treated like any normal text file.

MMI Dump

The following file was produced by performing a DUMP MMI -> P3 to a PC, as described
above. This file shows the Converter default settings.
so that the text columns line-up. Note that in the list below, `menus' have been
highlighted (bold) to make the list easier to use.
0.00 %
0.00 %
0.00 %
0.00 %
0.00 %
0.0 %
0.0 %
0.0 %
0.0 %
200.00 %
0.00 %
0.00 %
0 DEG
0.00 VOLTS
0.00 VOLTS
0.00 VOLTS
0.00 VOLTS
0.00 VOLTS
......ANOUT 1 (A7)
[55 ] =
......ANOUT 2 (A8)
[56 ] =
......START (C3)
[68 ] = OFF
......DIGITAL INPUT C4 [69 ] = OFF
......DIGITAL INPUT C5 [70 ] = OFF
......DIGIN 1 (C6)
[71 ] = OFF
......DIGIN 2 (C7)
[72 ] = OFF
......DIGIN 3 (C8)
[73 ] = OFF
......DIGOUT 1 (B5)
[74 ] = ON
......DIGOUT 2 (B6)
[75 ] = ON
......DIGOUT 3 (B7)
[76 ] = OFF
......RAISE/LOWER O/P [264 ] =
......PID OUTPUT
[417 ] =
......PID CLAMPED
[416 ] = FALSE
......PID ERROR
[415 ] =
......SPT SUM OUTPUT
[86 ] =
......RAMP OUTPUT
[85 ] =
......SPEED SETPOINT
[63 ] =
......TERMINAL VOLTS
[57 ] =
......BACK EMF
[60 ] =
......TACH INPUT (B2) [308 ] =
......ENCODER
[206 ] =
....SETUP PARAMETERS
......RAMPS
........RAMP ACCEL TIME [2
........RAMP DECEL TIME [3
........CONSTANT ACCEL
[4
........RAMP HOLD
[118 ] = OFF
........RAMP INPUT
[5
........ % S-RAMP
[266 ] =
........RAMPING THRESH. [286 ] =
........AUTO RESET
[287 ] = ENABLED
........EXTERNAL RESET
[288 ] = DISABLED
0.00 VOLTS
0.00 VOLTS
0.00 %
0.00 %
0.00 %
0.00 %
0.00 %
0.00 %
0.0 %
0.0 %
0.0 %
0 RPM
] =
0.1 SECS
*
] =
0.1 SECS
*
] = ENABLED
] =
0.00 %
2.50 %
0.50 %
590 Series DC Digital Converter