Parker 590 series Product Manual page 152

Dc digital converter
Hide thumbs Also See for 590 series:
Table of Contents

Advertisement

6-62
Programming Your Application
NORMALISED dv/dt
1. RATE CAL = 0.00: Allows an externally generated rate signal to be used in place of the
calculated value described above. This rate signal must be normalised to 100% for maximum
line ramp rate. Useful for large line ramp rates (>100 Secs)
2. RATE CAL not 0.00: Allows the internally calculated rate value to be monitored.
TENSION SCALER
Scales the Tension Demand which is directly connected from the Taper Calculator.
TENS+COMP
Reserved parameter for use by Parker SSD Drives.
INERTIA COMP O/P
Monitor point on the total inertia compensations.
Range: -300.00 to 300.00 %
Range: -3.0000 to 3.0000 %
Range: -200.00 to 200.00 %
590 Series DC Digital Converter