Certificates And Approvals; Ce Mark; C-Tick Mark; Ex Approval - Endress+Hauser Proline Promass 80A Technical Information

Coriolis mass flow measuring system the single-tube system for highly accurate measurement of very small flows
Hide thumbs Also See for Proline Promass 80A:
Table of Contents

Advertisement

Proline Promass 80A, 83A

CE mark

C-Tick mark

Ex approval

Sanitary compatibility

FOUNDATION Fieldbus
certification
PROFIBUS DP/PA
certification

MODBUS certification

Other standards and
guidelines
Pressure measuring device
approval
Endress+Hauser

Certificates and approvals

The measuring system is in conformity with the statutory requirements of the EC Directives.
Endress+Hauser confirms successful testing of the device by affixing to it the CE mark.
The measuring system is in conformity with the EMC requirements of the Australian Communication and
Media Authority (ACMA).
Information about currently available Ex versions (ATEX, FM, CSA´, IECEx, NEPSI) can be supplied by your
Endress+Hauser Sales Centre on request. All explosion protection data are given in a separate documentation
which is available upon request.
• 3A approval
• EHEDG-tested
The flowmeter has passed all the test procedures implemented and has been certified and registered by the
Fieldbus Foundation. The flowmeter thus meets all the requirements of the specifications listed below:
• Certified to FOUNDATION Fieldbus specification
• The flowmeter meets all the specifications of the FOUNDATION Fieldbus-H1
• Interoperability Test Kit (ITK), revision status 5.01 (Certification on request)
• The device can also be operated in conjunction with other-make certified devices
• Physical Layer Conformance Test of the Fieldbus Foundation
The flow device has successfully passed all the test procedures carried out and is certified and registered by the
PNO (PROFIBUS User Organization). The device thus meets all the requirements of the following
specifications:
• Certified to PROFIBUS Profile Version 3.0 (device certification number: on request)
• The device can also be operated with certified devices of other manufacturers (interoperability)
The measuring device meets all the requirements of the MODBUS/TCP conformity and integration test and
has the "MODBUS/TCP Conformance Test Policy, Version 2.0". The measuring device has successfully passed
all the test procedures carried out and is certified by the "MODBUS/TCP Conformance Test Laboratory" of the
University of Michigan.
• EN 60529
Degrees of protection by housing (IP code).
• EN 61010-1
Protection Measures for Electrical Equipment for Measurement, Control, Regulation and Laboratory
Procedures.
• IEC/EN 61326
"Emission in accordance with Class A requirements" Electromagnetic compatibility (EMC requirements).
• NAMUR NE 21
Electromagnetic compatibility (EMC) of industrial process and laboratory control equipment.
• NAMUR NE 43
Standardisation of the signal level for the breakdown information of digital transmitters with analogue
output signal.
• NAMUR NE 53
Software of field devices and signal-processing devices with digital electronics
Flow meters with a nominal diameter smaller or equal to DN 25 are covered by Art. 3(3) of the European
directive 97/23/EC (Pressure Equipment Directive) and are designed according to sound engineering practice.
For larger nominal diameters, optional approvals according to Cat. II/III are available when required (depends
on fluid and process pressure).