Device
(S) + 40 4-wire CH2 Factory default offset value
(S) + 41 4-wire CH2 Factory default offset value
(S) + 42 4-wire CH2 Factory default gain value
(S) + 43 4-wire CH2 Factory default gain value
Q64RD
(S) + 44 4-wire CH2 User range settings offset value
(S) + 45 4-wire CH2 User range settings offset value
(S) + 46 4-wire CH2 User range settings gain value
(S) + 47 4-wire CH2 User range settings gain value
(S) + 40 4-wire CH2 Factory default offset value (L)
(S) + 41 4-wire CH2 Factory default offset value (H)
(S) + 42 4-wire CH2 Factory default gain value (L)
Q64RD
(S) + 43 4-wire CH2 Factory default gain value (H)
-G
(S) + 44 4-wire CH2 User range settings offset value (L)
(S) + 45 4-wire CH2 User range settings offset value (H)
(S) + 46 4-wire CH2 User range settings gain value (L)
(S) + 47 4-wire CH2 User range settings gain value (H)
(S) + 48
4-wire CH2 User range settings offset resistance value (L)
(S) + 49
4-wire CH2 User range settings offset resistance value (H)
(S) + 50
4-wire CH2 User range settings gain resistance value (L)
(S) + 51
4-wire CH2 User range settings gain resistance value (H)
(S) + 52 3-wire CH3 Factory default offset value
(S) + 53 3-wire CH3 Factory default offset value
(S) + 54 3-wire CH3 Factory default gain value
(S) + 55 3-wire CH3 Factory default gain value
Q64RD
(S) + 56 3-wire CH3 User range settings offset value
(S) + 57 3-wire CH3 User range settings offset value
(S) + 58 3-wire CH3 User range settings gain value
(S) + 59 3-wire CH3 User range settings gain value
(S) + 52 3-wire CH3 Factory default offset value (L)
(S) + 53 3-wire CH3 Factory default offset value (H)
(S) + 54 3-wire CH3 Factory default gain value (L)
Q64RD
(S) + 55 3-wire CH3 Factory default gain value (H)
-G
(S) + 56 3-wire CH3 User range settings offset value (L)
(S) + 57 3-wire CH3 User range settings offset value (H)
(S) + 58 3-wire CH3 User range settings gain value (L)
(S) + 59 3-wire CH3 User range settings gain value (H)
(S) + 60
3-wire CH3 User range settings offset resistance value (L)
(S) + 61
3-wire CH3 User range settings offset resistance value (H)
(S) + 62
3-wire CH3 User range settings gain resistance value (L)
(S) + 63
3-wire CH3 User range settings gain resistance value (H)
(S) + 64 4-wire CH3 Factory default offset value
(S) + 65 4-wire CH3 Factory default offset value
(S) + 66 4-wire CH3 Factory default gain value
(S) + 67 4-wire CH3 Factory default gain value
Q64RD
(S) + 68 4-wire CH3 User range settings offset value
(S) + 69 4-wire CH3 User range settings offset value
(S) + 70 4-wire CH3 User range settings gain value
(S) + 71 4-wire CH3 User range settings gain value
1 Setting is not necessary. If setting is made, the offset/gain values will not be read properly.
App. - 16
1
Control data
(3/4)
Item
MELSEC-Q
Set data
Setting range Set by
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
App. - 16

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Q64rd-g

Table of Contents