Printer Gamma Sensor Adjustment - Konica Minolta bizhub pro c500 User Manual

Hide thumbs Also See for bizhub pro c500:
Table of Contents

Advertisement

[25] Printer Gamma Sensor Adjustment

Use this function to make various adjustments concerning the gamma sensor.
Key Operator Mode Screen
Procedure
1 Touch [25] Printer Gamma Sensor adjustment on the Key Operator Mode Screen
to display the Printer Gamma Sensor Adjustment Screen.
2 Select the desired adjustment item on the screen. Six items are provided: LS200,
LS150, DS200, DS150, CONTONE, and ED.
Touch NEXT ADJUSTMENT or PREVIOUS ADJUSTMENT to move to the next or
previous adjustment item.
NOTE:
Some adjustment items cannot be displayed if the screen is specified as OFF
state in the Memory Switch setting.
Touching Adj. data reset will display the Reset Confirmation Screen. Touch YES
to reset the adjustment value to the initial state, or touch NO to cancel.
3 Touch COPY SCREEN to move to the Basic Screen to print a chart.
Load several sheets of A4 paper on the Multi-sheet bypass tray, then press
[START] to output the test chart.
When output is completed, the Printer Gamma Sensor Adjustment Screen will be
restored, with the message "Please load output paper in Platen and push
[START] button" displayed.
4 Place the test chart face down on the platen glass with green arrow "b" pointing
at the left side as shown below, and put about 10 sheets of blank copy paper on
top of the chart.
Green
arrow
Printer Gamma Sensor Adjustment Screen
Place the chart
FACE DOWN
14-57