Power Management

Fan failure alarms are issued as soon as the fan failure condition is detected and are canceled when the
fan failure condition clears. Temperature alarms are issued as soon as the temperature reaches the
threshold temperature and are canceled when the temperature drops more than 5 degree C below the
threshold. 5 degree C is a hysteresis value designed to prevent toggling alarms.
An LED on the supervisor engine indicates whether an alarm has been issued.
When the system issues a major alarm, it starts a timer whose duration depends on the alarm. If the alarm
is not canceled before the timer expires, the system takes emergency action to protect itself from the
effects of overheating. The timer values and the emergency actions depend on the type of supervisor
engine.
Refer to the Catalyst 4500 Series Switch Module Installation Guide for information on LEDs, including
Note
the startup behavior of the supervisor engine system LED.
Table 12-4 describes the alarms.
Table 12-4
Alarms on Supervisor Engine 6-E, Supervisor Engine 6L-E, and Supervisor Engine 7-E
Event
Card temperature exceeds the
critical threshold.
Card temperature exceeds the
shutdown threshold.
Supervisor engine fails power-on
self-test (POST).
Chassis fan tray fails.
Chassis temperature exceeds the
warning threshold.
Chassis fan tray experiences
partial failure.
Power Management
This section describes the power management feature in the Catalyst 4500 series switches. It includes
the following topics:
Software Configuration Guide—Release IOS XE 3.3.0SG and IOS 15.1(1)SG
12-6
Alarm
Supervisor LED
Type
Color
Major
Red
Major
Red
Major
Red
Major
Red
Minor
Orange
Minor
Orange
Power Management for the Catalyst 4500 Series Switches, page 12-7
Powering Down a Module, page 12-19
Power Management for the Catalyst 4948 Switches, page 12-20
Chapter 12
Environmental Monitoring and Power Management
Timeout
Description and Action
15 min
Syslog message displays when the alarm is
issued.
See
Table 12-2
30 sec
Syslog message displays when the alarm is
issued.
See
Table 12-2
Syslog message displays.
Supervisor engine fails to come up.
30 sec
Syslog message displays when the alarm is
issued.
See
Table 12-2
Syslog message when the alarm is issued.
Syslog message when the alarm is issued.
for the action on timeout.
for the action on timeout.
for the action on timeout.