Supervisor Engine Redundancy Guidelines and Restrictions
Here are the steps:
Step 1
Clear the offending configuration (that caused an MCL) while the standby supervisor engine is in
standby cold (RPR) state.
Enter the redundancy config-sync ignore mismatched-commands EXEC command at the active
Step 2
standby supervisor engine.
Perform write memory.
Step 3
Reload the standby supervisor engine with the redundancy reload peer command.
Step 4
If you configure Supervisor Engine V-10GE to use both Gigabit Ethernet and 10-Gigabit Ethernet
uplinks without WS-X4302-GB in slot 10, module 10 is disabled and you cannot rollback the
configuration to use gigabit ports.
Enter the following commands to recover:
config t
hw-module uplink select tengigabitethernet
mode
!
ctrl z
wr me
redundancy reload shelf
//The switch reloads
config t
hw-module uplink select gigabitethernet
!
ctrl z
wr me
redundancy reload shelf
ethernet port(s) ON and the ten gigabit ethernet port(s) Off
RPR requires Cisco IOS Release 12.1(12c)EW, Release 12.1(19)E or later releases. SSO requires
Cisco IOS Release 12.2(20)EWA or later releases.
The Catalyst 4507R switch and the 4510R switch are the only Catalyst 4500 series switches that
support supervisor engine redundancy.
In Cisco IOS Release 12.2(25)SG and later releases on a Catalyst 4507R series switch, 10-Gigabit
Ethernet and Gigabit Ethernet uplinks are concurrently usable.
Redundancy requires both supervisor engines in the chassis to have the same components (model,
memory, NFL daughter card), and to use the same Cisco IOS software image.
When the WS-X4516 active and redundant supervisor engines are installed in the same chassis, the
four uplink ports (Gig1/1, Gig2/1, Gig 1/2, and Gig2/2) are available.
The active and redundant supervisor engines in the chassis must be in slots 1 and 2.
Each supervisor engine in the chassis must have its own flash device and console port connections
to operate the switch on its own.
Each supervisor engine must have a unique console connection. Do not connect a Y cable to the
console ports.
Supervisor engine redundancy does not provide supervisor engine load balancing.
Software Configuration Guide—Release IOS XE 3.3.0SG and IOS 15.1(1)SG
9-6
Chapter 9
Configuring Supervisor Engine Redundancy Using RPR and SSO on Supervisor Engine 6-E and Supervisor
// The switch will reload with all 10 modules working ok
// The switch reloads with module 10 active with the gigabit
// This sets the switch back to default
// This sets the switch to the desired link
OL-25340-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents